IntroductionDespite the prevalence of shunt failure in the treatment of hydrocephalus and the near-constant need for shunt revisions, there are a limited number of methods that yield quick, quantifiable measures of catheter obstruction. We developed and assessed a gravity-driven device that measures flow through ventricular catheters. The model provides neurosurgeons with a quick, simple device that can send useful data to researchers. It can also be used by researchers to quantitatively compare catheter obstruction between different models of catheters. The model was used in this study to quantitatively analyze unused ventricular catheters used in the treatment of hydrocephalus; failed hydrocephalus catheters from our catheter biorepository were also quantitatively analyzed using the same device. The mechanisms of catheter obstruction are still poorly understood, but the literature suggests that resistance to fluid flow plays a significant role. MethodsCatheters of three manufacturing companies were inserted into the benchtop model, which records time, flow rate, and pressure data using sensors. The relative resistances of catheters across six design models were evaluated. Experiments were performed to evaluate changes in the relative resistance of a catheter when the catheters holes were progressively closed. Relative resistance of explanted catheters from our catheter biorepository was also measured. ResultsExperimental results showed significant differences (P < 0.05) between the relative resistances of different catheter models just after being removed from their packaging. Furthermore, a trend of increasing resistance was observed in the experiments on catheters with manually plugged ventricular catheter holes. Data from five individual benchtop models were compared, and the differences in measured data between the models were found to be negligible. A significant increase (P < 0.05) in relative resistance was observed in explanted catheters. ConclusionThe current study is meant both to validate the proposed model and to examine data on differences in relative resistance among catheter models. From these experiments, we can rapidly correlate clinical patient cohorts to identify mechanisms of luminal shunt obstruction. Collecting data for predictive analyses of potential patient outcomes is an area of potential future work, assuming sufficient sample size.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reliability and Performance of the IRRAflow® System for Intracranial Lavage and Evacuation of Hematomas - A Technical Note 97%
- Intrathecal catheter implantation decreases cerebrospinal fluid dynamics in cynomolgus monkeys 95%
- Recognition and Differentiation of Dural Puncture Click Sensation: A Subjective and Objective Prospective Study of Dural Puncture Forces Using Fine-Gauge Spinal Needles 93%
Similar papers in this journal
- De novo Powered Air-Purifying Respirator Design and Fabrication for Pandemic Response 90%
- Sustained In Vivo Perfusion of a Re-Endothelialized Tissue Engineered Kidney Graft in a Human-Scale Animal Model 89%
- Methods for Processing and Analyzing Images of Vascularized Micro-Organ and Tumor Systems 89%
Similar papers in this journal
- Switching the left and the right hearts: A novel bi-ventricle mechanical support strategy with spared native single-ventricle 93%
- Precision in Spinal Cord Injury Research: A Novel Electromagnetic Impactor for a Consistent Porcine Model 92%
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 91%
Similar papers in this journal
- Hemodynamics with Mechanical Circulatory Support Devices Using a Cardiogenic Shock Model 93%
- Newly developed silicone airway stent (GINA stent): Mechanical characteristics and performance evaluation in pigs 93%
- A Niclosamide-releasing hot-melt extruded catheter prevents Staphylococcus aureus experimental biomaterial-associated infection 93%
Similar papers in this journal
- Three-dimensional modeling of flow through microvascular beds and surrounding interstitial spaces 90%
- Dissecting contributions of pulmonary arterial remodeling to right ventricular afterload in pulmonary hypertension 89%
- Convective forces contribute to post-traumatic degeneration after spinal cord injury 88%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.