Photoacoustic imaging reveals transient decrease of oxygenation in murine blood due to monoclonal IgG4 antibody
Khadria, A.; Paavola, C. D.; Maslov, K.; Brown-Augsburger, P. L.; Grealish, P. F.; Lozano, E.; Blankenship, R. L.; Cao, R.; Shi, J.; Beals, J. M.; Oladipupo, S. S.; Wang, L. V.
Show abstract
Over 100 monoclonal antibodies have been approved by the FDA for clinical use; however, a paucity of knowledge exists regarding the injection site behavior of these formulated therapeutics, i.e., the effect of antibody and formulation on the tissue around the injection site and vice versa. In this report, we injected a near-infrared dye-labeled IgG4 isotope control antibody into the subcutaneous space in mouse ears to analyze the injection site dynamics, including quantifying molecular movement. Surprisingly, we discovered that the antibody reduces the local blood oxygen saturation levels in mice after prolonged anesthesia without affecting the total hemoglobin content and oxygen extraction fraction. The local oxygen saturation results open a new pathway to study the functional effects of monoclonal antibodies.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Enhanced capillary delivery with nanobubble-mediated blood-brain barrier opening and advanced high resolution vascular segmentation 95%
- Low-frequency ultrasound-mediated blood-brain barrier opening enables non-invasive lipid nanoparticle RNA delivery to glioblastoma 93%
- Transdermal Delivery of Ultradeformable Cationic Liposomes Complexed with miR211-5p (UCL-211) Stabilizes BRAFV600E+ Melanocytic Nevi 92%
Similar papers in this journal
- Machine learning-enabled cancer diagnostics with widefield polarimetric second-harmonic generation microscopy 93%
- 2-photon imaging of fluorescent proteins in living swine 93%
- Real-time, functional intra-operative localization of rat cavernous nerve network using near-infrared cyanine voltage-sensitive dye imaging 93%
Similar papers in this journal
Similar papers in this journal
- Open-top Bessel beam two-photon light sheet microscopy for three-dimensional pathology 94%
- A novel method (RIM-Deep) enhances imaging depth and resolution stability of deep-cleared brain tissue in inverted confocal microscopy 93%
- Label-free imaging of immune cell dynamics in the living retina using adaptive optics 93%
Similar papers in this journal
- High-resolution radioluminescence microscopy of FDG uptake in an engineered 3D tumor-stoma model 93%
- A Phase I Study of a PARP1-targeted Topical Fluorophore for the Detection of Oral Cancer 92%
- Combined, yet Separate: cocktails of carriers (not drugs) for α-particle therapy of solid tumors expressing moderate-to-low levels of targetable markers 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.