On the performance of multi-compartment relaxometry for myelin water imaging - Intra-subject and inter-protocol reproducibility
Chan, K.-S.; Chamberland, M.; Marques, J. P.
Show abstract
We evaluate the test-retest repeatability and study the tissue properties of multicompartment relaxometry-based myelin water imaging (MCR-MWI) derived from different gradient echo (GRE) acquisition settings. Additionally, the variable flip angle acquisition scheme is optimised based on numerical simulations to reduce the acquisition time of MCR-MWI in a clinically practical range without using advanced image acquisition methods. For the test-retest analysis, in vivo imaging was performed to collect data from three healthy volunteers in two identical sessions. Three GRE sequence settings with different echo times and repetition times imitating various scanner setups were evaluated. The in vivo data was also used to validate the optimal variable flip angle combination derived from simulations. Bundle-specific profiles of MCR-MWI derived microstructural parameters were investigated, as well as the cross-correlations of those parameters. Good cross-session repeatability is observed for MCR-MWI. While good correlations can also be found in myelin water fraction (MWF) across protocols, systematic differences, particularly for protocols with different repetition times, are observed. Numerical simulations indicate that MCR-MWI can be performed with a minimum of three flip angles covering a wide range of T1 weighting without adding significant measurement bias and the result is supported by the in vivo experiment allowing whole brain 1.5mm isotropic MWF maps to be acquired in 9 minutes. Bundles-specific MWF analysis reveals that certain white matter bundles are similar in all three participants. We also found that microstructure relaxation parameters have low correlations with MWF. MCR-MWI is a reproducible measure of myelin. However, attention should be paid to considering the protocol related MWF differences for comparison studies, especially when different repetition times are used as this can introduce biases up to 0.5% of MWF in our tested protocols. The optimised flip angle acquisition scheme can reduce the total scan time to 40% of the original implementation without significant quality degradation. Highlights- Multi-compartment relaxometry based myelin water imaging (MCR-MWI) can be performed with data comprising as few as 3 flip angles without introducing substantial bias or instability in the fitting procedure; - MCR-MWI is a reproducible measure of myelin water fraction (MWF) and incorporating DWI can further improve the measurement reproducibility; - MCR-MWI allows the acquisition of whole brain 1.5mm isotropic MWF maps in 9 minutes, even without the use of advanced model-based reconstructions; - Small MWF bias can present in cross-protocol comparison if the MT effect is not constant across GRE protocols (e.g., different TRs or flip angle combinations); - Compartmental relaxation parameters derived from MCR-MWI possess complimentary information beyond myelin water concentration.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Error quantification in multi-parameter mapping facilitates robust estimation and enhanced group level sensitivity 98%
- Multi-parametric quantitative spinal cord MRI with unified signal readout and image denoising 98%
- NOise Reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing 98%
Similar papers in this journal
- Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA-based and AI-based Denoising 97%
- Axisymmetric diffusion kurtosis imaging with Rician bias correction: A simulation study 97%
- Accelerated multi-shell diffusion MRI with Gaussian process estimated reconstruction of multi-band imaging 97%
Similar papers in this journal
- Human gray matter microstructure mapped using Neurite Exchange Imaging (NEXI) on a clinical scanner 98%
- Denoising Diffusion MRI: Considerations and implications for analysis 98%
- ACID: A Comprehensive Toolbox for Image Processing and Modeling of Brain, Spinal Cord, and Post-mortem Diffusion MRI Data 97%
Similar papers in this journal
- High-frequency longitudinal white matter diffusion- & myelin-based MRI database: reliability and variability 98%
- Diffusion MRI Head Motion Correction Methods are Highly Accurate but Impacted by Denoising and Sampling Scheme 97%
- Reproducibility and reliability of Free-Water-corrected Diffusion Tensor Imaging of the brain: Revisited 97%
Similar papers in this journal
- Tailored Magnetic Resonance Fingerprinting 96%
- Advancing High-Resolution 7T Diffusion MRI: Evaluating Phase-Encoding Correction Strategies for Distortion Correction from Basic to Four-Way Acquisitions 96%
- Influence of preprocessing, distortion correction and cardiac triggering on the quality of diffusion MR images of spinal cord 96%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.