Modeling the carbon-dioxide response function in fMRI under task and resting-state conditions
Shams, S.; Prokopiou, P. C.; Esmaelbeigi, A.; Chen, J. J.; Mitsis, G.
Show abstract
Conventionally, cerebrovascular reactivity (CVR) is estimated as the amplitude of the hemodynamic response to vascular stimuli. While the CVR amplitude has established clinical utility, the temporal characteristics of CVR have been increasingly explored and may yield even more pathology-sensitive parameters. This work is motivated by the current need to evaluate the feasibility of dCVR modeling in various noise conditions. In this work, we present a comparison of several recently published model-based deconvolution approaches for estimating h(t), including maximum a posterior likelihood (MAP), inverse logit (IL), canonical correlation analysis (CCA), and basis expansion (using Gamma and Laguerre basis sets). To aid the comparison, we devised a novel simulation framework that allowed us to target a wide range of SNRs, ranging from 10 to -7 dB, representative of both task and resting-state CO2 changes. In addition, we built ground-truth h(t) into our simulation framework, overcoming the practical limitation that the true h(t) is unknown in methodological evaluations. Moreover, to best represent realistic noise found in fMRI scans, we extracted it from in-vivo resting-state scans. Furthermore, we introduce a simple optimization of the CCA method (CCAopt) and compare its performance to these existing methods. Our findings suggest that model-based methods can reasonably estimate dCVR even amidst high noise, and in a manner that is largely independent of the underlying model assumptions for each method. We also provide a quantitative basis for making methodological choices, based on the desired dCVR parameters, the estimation accuracy and computation time. The BEL method provided the highest accuracy and robustness, followed by the CCAopt and IL methods. Of the three, the CCAopt method required the lowest computational time. These findings lay the foundation for wider adoption of dCVR estimation in CVR mapping.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Physiological noise modeling in fMRI based on the pulsatile component of photoplethysmograph 97%
- Identification of Physiological Response Functions to Correct for Fluctuations in Resting-State fMRI related to Heart Rate and Respiration 97%
- BOLD response is more than just magnitude: improving detection sensitivity through capturing hemodynamic profiles 97%
Similar papers in this journal
- Simultaneous Confidence Regions for Image Excursion Sets: a Validation Study with Applications in fMRI 97%
- Increasing spectral DCM flexibility and speed by leveraging Julia's ModelingToolkit and automated differentiation 96%
- BOLDsωimsuite: A new software suite for forward modeling of the BOLD fMRI signal 96%
Similar papers in this journal
- Robust constrained weighted least squares for in vivo human cardiac diffusion kurtosis imaging 96%
- Training Data Distribution Significantly Impacts the Estimation of Tissue Microstructure with Machine Learning 96%
- Axisymmetric diffusion kurtosis imaging with Rician bias correction: A simulation study 95%
Similar papers in this journal
- Detection of Transient Neurotransmitter Response Using Personalized Neural Networks 94%
- Group-Level Analysis of Induced Electric Field in Deep Brain Regions by Different TMS Coils 92%
- A Detector Block-Pairwise Dead Time Correction Method for Improved Quantitation with a Dedicated BrainPET Scanner 92%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.