The Effect of Negative Pressure on IOP in the Living Human Eye
Fazio, M. A.; Bianco, G.; Karuppanan, U.; Hubbard, M.; Bruno, L.; Girkin, C. A.
Show abstract
PO_SCPLOWURPOSEC_SCPLOW To quantify the effect of negative pressure applied to the anterior surface of the eye on absolute IOP. SO_SCPLOWUBJECTSC_SCPLOWParticipants, and/or Controls. Three eyes from three research-consented brain-dead organ donors. MO_SCPLOWETHODSC_SCPLOWAir-tight goggles connected to a negative pressure (NP) pump (Mercury Multi-pressure Dial (MPD); Equinox Ophthalmic, Inc., CA) were tested on three research consented brain-dead organ donors. The MPD was set to generate a vacuum of -20mmHg. A baseline IOP of 10, 20, and 30mmHg was sequentially set by adjusting the height of a balanced salt solution bottle connected to the cornea through a 20G needle. IOP was manually annotated at time = 0s, right before turning on the vacuum pump; after a few seconds with the vacuum pump ON; at 60s; at 120s, right before turning the pump OFF; at 240s with the pump OFF (recovery). Three repetitions per each test at varying baseline IOP were taken for a total of nine series of measures per eye. MO_SCPLOWAINC_SCPLOW OO_SCPLOWUTCOMEC_SCPLOW MO_SCPLOWEASURESC_SCPLOWIOP change with exposure to NP. RO_SCPLOWESULTSC_SCPLOWEye1 and 3 showed an immediate reduction in IOP at all baselines immediately following activation of the MPD NP pump; Eye2 showed an opposite response to NP. Eye1 and 3 showed a reduction in IOP at all baselines with NP pump ON for 60s and 120s, while Eye 2 showed a consistent increase in IOP. After 120s from turning NP OFF (time=240s), IOP partially recovered to its baseline in all eyes. CO_SCPLOWONCLUSIONSC_SCPLOWThis study is the first to evaluate changes in manometrically-measured intracameral IOP due to NP applied to the ocular surface in living conditions. The inconsistent response of IOP following exposure to negative pressure warrants further investigations on the mechanism underlaying IOP lowering by NP.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- The learning curve of murine subretinal injection among clinically trained ophthalmic surgeons 96%
- Relating Standardized Automated Perimetry Performed with Stimulus Sizes III and V in Eyes With Field Loss due to Glaucoma and NAION 96%
- Advanced Retinal Imaging and Ocular Parameters of the Rhesus Macaque Eye 96%
Similar papers in this journal
- The Structural Layers of the Porcine Iris Exhibit Inherently Different Biomechanical Properties 96%
- Longitudinal in vivo changes in radial peripapillary capillaries and optic nerve head structure in non-human primates with early experimental glaucoma 95%
- Changes in Iris Stiffness and Permeability in Primary Angle Closure Glaucoma 94%
Similar papers in this journal
Similar papers in this journal
- Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation 96%
- Profiling IOP-responsive genes in anterior and posterior ocular tissues in the rat CEI glaucoma model 95%
- Intracameral Puncture Lowers Intraocular Pressure and Triggers an Immune Response in the Conventional Outflow Tract 95%
Similar papers in this journal
- Automated vision screening of children using a mobile graphic device 95%
- Increasing frequency of hospital admissions for retinal detachment and vitreo-retinal surgery in England 2000-2018 93%
- Dense Optic Nerve Head Deformation Estimated using CNN as a Structural Biomarker of Glaucoma Progression 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.