ObjectivesTo investigate mechanistically the effects of fiber scanning speed (vfiber) and fiber tip-to-stone standoff distance (SD) on dusting efficiency during Holmium (Ho): YAG laser lithotripsy (LL) Materials and MethodsPre-soaked BegoStone samples (23 x 23 x 4 mm, W x L x H) were treated in water using a clinical Ho:YAG laser in dusting mode (0.2 J pulse energy delivered at 20 Hz frequency) at three different SDs (0.10, 0.25 and 0.50 mm) with vfiber in the range of 0 to 10 mm/s. Stone damage was quantified by optical coherence tomography, bubble dynamics were captured by high-speed imaging, and associated pressure transients were measured using a needle hydrophone. To compare photothermal ablation vs. cavitation in stone dusting, the experiments were further repeated in air (photothermal ablation only), and in water with the fiber tip advanced at a short (0.25 mm) offset distance (OSD) from a ureteroscope to mitigate the bubble collapse toward the stone surface, thus eliminating cavitation-induced damage. ResultsCompared to the craters produced by a stationary fiber, the damage troughs produced by a scanning fiber after 100 pulses were significantly larger in volume. The optimal vfiber for maximum dusting efficiency was found to be 3.5 mm/s for SD = 0.10 [~] 0.25 mm, resulting in long (17.5 mm), shallow (0.14 - 0.15 mm) and narrow (0.3 - 0.4 mm) troughs. In contrast, the maximum stone damage was produced at an optimal vfiber of 0.5 mm/s for SD = 0.50 mm, which generates much shorter (2.5 mm), yet deeper (0.35 mm) and wider (1.4 mm) troughs. Greater stone damage was produced in water than in air, especially at vfiber = 0 - 3.5 mm/s. With the scope end placed near the fiber tip, stone damage could be significantly reduced in water by 29% - 58% for SD = 0.10 mm, by 51% - 82% for SD = 0.25 mm, and by 66% - 100 % for SD = 0.50 mm, compared to those produced without the scope. Together, these findings suggest that cavitation plays an indispensable role in stone dusting by scanning treatment. Moreover, under clinically relevant vfiber (1 [~] 3 mm/s), dusting at SD = 0.5 mm (i.e., non-contact mode) may leverage higher frequency of the laser (e.g., 40 to 120 Hz) to harvest the full potential of cavitation damage while significantly reducing the procedure time, compared to its counterpart at SD = 0.1 mm (i.e., contact mode) that promotes photothermal ablation. ConclusionDusting efficiency during Ho:YAG LL may be substantially improved by utilizing the optimal combination of vfiber and SD for a given frequency.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage 95%
- Interferometric imaging of thermal expansion for temperature control in retinal laser therapy 93%
- Diamond Raman Laser and Yb Fiber Amplifier for In Vivo Multiphoton Fluorescence Microscopy 93%
Similar papers in this journal
- Cell viability assessment associated with a contact of gas bubbles produced by femtosecond laser breakdown in cell culture media 94%
- Renal tubular function and morphology revealed in kidney without labeling using three-dimensional dynamic optical coherence tomography 93%
- Highly reliable, targeted photothermal cancer therapy combined with thermal dosimetry using indocyanine green lactosome 92%
Similar papers in this journal
- Optical bench simulation for intraocular lenses using field-tracing technology 93%
- Quantitative analysis of calcium oxalate monohydrate and dihydrate for elucidating the formation mechanism of calcium oxalate kidney stones 92%
- The Dynamic Response of Human Lungs Due to Underwater Shock Wave Exposure 91%
Similar papers in this journal
Similar papers in this journal
- High precision fluorescence tomography-guided system for pre-clinical radiation research: system design and validation 94%
- Treatment planning for photodynamic therapy of abscess cavities using patient-specific optical properties measured prior to illumination 94%
- Contrast-enhanced photon-counting micro-CT of tumor xenograft models 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.