The Future is 2D: Spectral-Temporal Fitting of Dynamic Magnetic Resonance Spectroscopy Data Provides Exponential Gains in Precision Over Conventional Approaches
Tal, A.
Show abstract
AO_SCPLOWBSTRACTC_SCPLOWO_ST_ABSPurposeC_ST_ABSMany MRS paradigms produce 2D spectral-temporal datasets, including diffusion-weighted, functional, hyperpolarized and enriched (13C, 2H) experiments. Conventionally, temporal parameters - such as T2, T1, or diffusion constants - are assessed by first fitting each spectrum independently, and subsequently fitting a temporal model (1D fitting). We investigated whether simultaneously fitting the entire dataset using a single spectral-temporal model (2D fitting) would improve the precision of the relevant temporal parameter. MethodsWe derived a Cramer Rao Lower Bound for the temporal parameters for both 1D and 2D approaches, for two experiments: A multi-echo (MTE) experiment, designed to estimate metabolite T2s; And a functional (fMRS) experiment, designed to estimate fractional change ({delta}) in metabolite concentrations. We investigated the dependence of the relative standard deviation of T2 in MTE and{delta} in fMRS. ResultsWhen peaks were spectrally distant, 2D fitting improved precision by approximately 20% relative to 1D fitting, regardless of the experiment and other parameter values. These gains increased exponentially as peaks drew closer. Dependence on temporal model parameters was weak to negligible. ConclusionOur results strongly support a 2D approach to MRS fitting where applicable, and particularly in nuclei such as 1H and 2H, which exhibit substantial spectral overlap.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 94%
- Simulation of the effect of diffusion on asymmetric spin echo based quantitative BOLD: An investigation of the origin of deoxygenated blood volume overestimation 94%
- Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution 94%
Similar papers in this journal
- MRS-Sim: Open-Source Framework for Simulating Realistic In Vivo-like MR Spectroscopy Data 95%
- Improving reproducibility of proton MRS brain thermometry: theoretical and empirical approaches 95%
- Quantifying transmembrane water exchange by diffusion NMR methods: From yeast cells to optic nerve ex vivo 95%
Similar papers in this journal
- Interpretable dimensionality reduction and classification of mass spectrometry imaging data in a visceral pain model via non-negative matrix factorization 93%
- Analysis of physiological noise in quantitative cardiac magnetic resonance 92%
- Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing 92%
Similar papers in this journal
- The statistical challenge of finding spontaneous changes in functional connectivity in high-dimensional fMRI data 92%
- Mechanistic model for human brain metabolism and the neurovascular coupling. 92%
- Linear discriminant analysis reveals hidden patterns in NMR chemical shifts of intrinsically disordered proteins 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.