Normative values of neuromelanin-sensitive MRI signal in older adults obtained using a standard protocol for acquisition and analysis
Al Haddad, R.; Chamoun, M.; Tardif, C.; Guimond, S.; Horga, G.; Rosa-Neto, P.; Cassidy, C.
Show abstract
BackgroundThe integrity and function of catecholamine neurotransmitter systems can be assessed using MRI sequences often referred to as neuromelanin-sensitive MRI (NM-MRI). The relevance of this method to neurodegenerative and psychiatric disorders is becoming increasingly evident, and it has potential as a clinical biomarker. To support such future applications, we report here the normative range of NM-MRI signal and volume metrics in cognitively normal older adults. Methods3 Tesla NM-MRI images and demographic and cognitive data were available from 152 cognitively normal older adults aged 53-86 years old at baseline; a subsample of 68 participants also had follow-up NM-MRI data collected around one-year later. NM-MRI images were processed to yield summary measures of volume and signal (contrast-to-noise ratio, CNR) for the substantia nigra (SN) and locus coeruleus (LC) using a recently developed software employing a fully automated algorithm. The extent of annual change in these metrics was quantified and tested for significance using 1-sample t-tests. ResultsBaseline SN signal (CNR) was 10.02% (left SN) and 10.28% (right) and baseline LC signal was 24.71% (left) and 20.42% (right). The only NM-MRI metric to show a significant annual change was a decrease in left SN volume. ConclusionWe report normative values for NM-MRI signal and volume in the SN and LC of cognitively normal older adults and normative values for their change over time. These values may help future efforts to use NM-MRI as a clinical biomarker for adults in this age range by facilitating identification of patients with extreme NM-MRI values.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Beware of White Matter Hyperintensities Causing Systematic Errors in Grey Matter Segmentations! 95%
- From Big Data to the clinic: methodological and statistical enhancements to implement the UK Biobank imaging framework in a memory clinic 95%
- Comparison of approaches to control for intracranial volume in research on the association of brain volumes with cognitive outcomes 94%
Similar papers in this journal
- Spinal cord MRI and MRS Detect Early-stage Alterations and Disease Progression in Friedreich Ataxia 95%
- Assessment of white matter hyperintensity severity using multimodal MRI in Alzheimer's Disease 95%
- Loss and Reorganisation of Superficial White Matter in Alzheimer’s disease: A Diffusion MRI study 95%
Similar papers in this journal
- Brain Iron Imaging Markers in the Presence of White Matter Hyperintensities 94%
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 94%
- Influence of preprocessing, distortion correction and cardiac triggering on the quality of diffusion MR images of spinal cord 93%
Similar papers in this journal
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.