Effect of pressure insole sampling frequency on peak force accuracy during running
Elstub, L. J.; Grohowski, L. M.; Wolf, D. N.; Owen, M. K.; Noehren, B.; Zelik, K. E.
Show abstract
Pressure sensing insoles enable us to estimate forces under the feet during activities such as running, which can provide valuable insight into human movement. Pressure insoles also afford the opportunity to collect more data in more representative environments than can be achieved in laboratory studies. One key challenge with real-world use of pressure insoles is limited battery life which restricts the amount of data that can be collected on a single charge. Reducing sampling frequency is one way to prolong battery life, at the cost of decreased measurement accuracy, but this trade-off has not been quantified, which hinders decision-making by researchers and developers. Therefore, we characterized the effect of decreasing sampling frequency on peak force estimates from pressure insoles (Novel Pedar, 100 Hz) across a range of running speeds and slopes. Data were downsampled to 50, 33, 25, 20, 16 and 10 Hz. Force peaks were extracted due to their importance in biomechanical algorithms trained to estimate musculoskeletal forces and were compared with the reference sampling frequency of 100 Hz to compute relative errors. Peak force errors increased exponentially from 0.7% (50 Hz) to 9% (10 Hz). However, peak force errors were <3% for all sampling frequencies down to 20 Hz. For some pressure insoles, sampling rate is inversely proportional to battery life. Therefore, these findings suggest that battery life could be increased up to 5x at the expense of 3% errors. These results are encouraging for researchers aiming to deploy pressure insoles for remote monitoring or in longitudinal studies.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Development and validation of 2D-LiDAR-based gait analysis instrument and algorithm 94%
- Validity and sensitivity of an inertial measurement unit-driven biomechanical model of motor variability for gait 93%
- Validity and reliability of inertial measurement units in active range of motion assessment in the hip joint 93%
Similar papers in this journal
- A single decreasing ramp friction sprint for torque-cadence relationship assessment during cycling 93%
- RACLET: the Ramp Above Critical Level Endurance Test to evaluate critical power in cycling. 92%
- RACLET: the Ramp Above Critical Level Endurance Test to evaluate critical force in isometric task. 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.