The gradient-based parameter optimization to determine membrane ionic current composition of human induced pluripotent stem cell-derived cardiomyocytes
Kohjitani, H.; Koda, S.; Himeno, Y.; Makiyama, T.; Yamamoto, Y.; Yoshinaga, D.; Wuriyanghai, Y.; Kashiwa, A.; Toyoda, F.; Zhang, Y.; Amano, A.; Noma, A.; Kimura, T.
Show abstract
1.Premature cardiac myocytes derived from human-induced pluripotent stem cells (hiPSC-CMs) show heterogeneous action potentials (APs), most probably because of different expression patterns of membrane ionic currents. We aim to develop a method of determining expression patterns of functional channels in terms of the whole-cell ionic conductances (Gx) using individual spontaneous AP configurations. However, it has been suggested that apparently identical AP configurations were obtained by different sets of ionic currents in a mathematical model of cardiac membrane excitation. If so, the inverse problem of Gx estimation might not be solved. We computationally tested the feasibility of the gradient-based optimization method. For realistic examination, conventional cell-specific models were prepared by superimposing the model output of AP on each experimental AP record by the conventional manual adjustment of Gxs of the baseline model. Then, Gxs of 4 ~ 6 major ionic currents of the cell-specific models were randomized within a range of {+/-}5 ~ 15% and were used as initial parameter sets for the gradient-based automatic Gxs recovery by decreasing the mean square error (MSE) between the target and model output. When plotted all data points of MSE - Gx relation during the optimization, we found that the randomized population of Gxs progressively converged to the original value of the cell-specific model with decreasing MSE. To confirm the absence of any other local minimum in the global search space, we mapped the MSE by randomizing Gxs over a range of 0.1 ~ 10 times the control. No additional local minimum of MSE was obvious in the whole parameter space besides the global minimum of MSE at the default model parameter.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Genetic algorithm-based personalized models of human cardiac action potential 96%
- Pacemaking function of two simplified cell models 95%
- Anticipation of ventricular tachyarrhythmias by a novel mathematical method: Further insights towards an early warning system in implantable cardioverter defibrillators 93%
Similar papers in this journal
- Sensitivity and uncertainty analysis of two human atrial cardiac cell models using Gaussian process emulators 96%
- Modeling depolarization delay, sodium currents, and electrical potentials in cardiac transverse tubules 95%
- Atrioventricular nodal reentrant tachycardia onset,sustainability, and spontaneous termination in rabbit atrioventricular node model with autonomic nervous system control 95%
Similar papers in this journal
- Reciprocal interaction between IK1 and If in biological pacemakers: A simulation study 97%
- HippoUnit: A software tool for the automated testing and systematic comparison of detailed models of hippocampal neurons based on electrophysiological data 94%
- Creating cell-specific computational models of stem cell-derived cardiomyocytes using optical experiments 94%
Similar papers in this journal
- On the Ca2+ elevation in vascular endothelial cells due to inositol trisphosphate-sensitive store receptor activation: a data-driven modeling approach 94%
- Neuronal Spike Shapes (NSS): A Straightforward Approach to Investigate Heterogeneity in Neuronal Excitability States. 94%
- Key Factors in the Cortical Response to Transcranial Electrical Stimulations--A Multi-Scale Modeling Study 92%
Similar papers in this journal
- Phenomenological models of NaV1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms. 96%
- Transmural and rate-dependent profiling of drug-induced arrhythmogenic risks through in silico simulations of multichannel pharmacology 95%
- Detection and categorization of severe cardiac disorders based solely on pulse interval measurements 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.