21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)
Clarke, W. T.; Hingerl, L.; Strasser, B.; Bogner, W.; Valkovic, L.; Rodgers, C. T.
Show abstract
A 3D density-weighted concentric ring trajectory (CRT) MRSI sequence is implemented for cardiac 31P-MRS at 7T. The point-by-point k-space sampling of traditional phase-encoded CSI sequences severely restricts the minimum scan time at higher spatial resolutions. Our proposed CRT sequence implements a stack of concentric rings trajectory, with a variable number of rings and planes spaced to optimise the density of k-space weighting. This creates flexibility in acquisition time, allowing acquisitions substantially faster than traditional phase-encoded CSI sequences, while retaining high SNR. We first characterise the signal-to-noise ratio and point spread function of the CRT sequence in phantoms. We then evaluate it at five different acquisition times and spatial resolutions in the hearts of five healthy participants at 7T. These different sequence durations are compared with existing published 3D acquisition-weighted CSI sequences with matched acquisition times and spatial resolutions. To minimise the effect of noise on the short acquisitions, low-rank denoising of the spatio-temporal data was also performed after acquisition. The proposed sequence measures 3D localised PCr/ATP ratios of the human myocardium in 2.5 minutes, 2.6 times faster than the minimum scan time for the acquisition-weighted phase-encoded CSI. Alternatively, in the same scan time a 1.7-times smaller nominal voxel volume can be achieved. Low-rank denoising reduced the variance of measured PCr/ATP ratios by 11% across all protocols. The faster acquisitions permitted by 7T CRT 31P-MRSI could make cardiac stress protocols or creatine kinase rate measurements (which involve repeated scans) more tolerable for patients without sacrificing spatial resolution.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T 96%
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 96%
- Cerebrospinal Fluid Flow within Ventricles and Subarachnoid Space Evaluated by Velocity Selective Spin Labeling MRI 95%
Similar papers in this journal
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 96%
- An in-vivo study of BOLD laminar responses as a function of echo time and static magnetic field strength 95%
- Temporal signal-to-noise changes in combined multiband- and slice-accelerated echo-planar imaging with a 20- and 64-channel coil 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.