A Leak-Free Head-Out Plethysmography System to Accurately Assess Lung Function in Mice
Bruggink, S. M.; Kentch, K. P.; Kronenfeld, J. M.; Renquist, B. J.
Show abstract
Mice are a valuable model for elegant studies of complex, systems-dependent diseases, including pulmonary diseases. Current tools to assess lung function in mice are either terminal or lack accuracy. We set out to develop a low-cost, accurate, head-out variable-pressure plethysmography system to allow for repeated, non-terminal measurements of lung function in mice. Current head-out plethysmography systems are limited by air leaks that prevent accurate measures of volume and flow. We designed an inflatable cuff that encompasses the mouses neck preventing air leak. We wrote corresponding software to collect and analyze the data, remove movement artifacts, and automatically calibrate each dataset. This software calculates inspiratory/expiratory volume, inspiratory/expiratory time, breaths per minute, enhanced pause, mid-expiratory flow, and end-inspiratory pause. To validate the use, we established our plethysmography system accurately measured tidal breathing, the bronchoconstrictive response to methacholine, sex and age associated changes in breathing, and breathing changes associated with house dust mite sensitization. Our estimates of volume, flow, and timing of breaths are in line with published estimates, we observed dose-dependent decreases in volume and flow in response to methacholine (P < 0.05), increased lung volume and decreased breathing rate with aging (P < 0.05), and that house dust mite sensitization decreased tidal volume and flow (P <0.05) while exacerbating the methacholine induced increases in inspiratory and expiratory time (P < 0.05). We describe an accurate, sensitive, low-cost, head-out plethysmography system that allows for longitudinal studies of pulmonary disease in mice. New & NoteworthyWe describe a variable-pressure head-out plethysmography system that can be used to assess lung function in mice. A balloon cuff that inflates around the mouses neck prevents air leak, allowing for accurate measurements of lung volume and air flow. Custom software facilitates system calibration, removes movement artifacts, and eases data analysis. The system was validated by measuring tidal breathing, responses to methacholine, and changes associated with house dust mite sensitization, sex, and aging. Contributions to StudyO_LIStephanie Bruggink: development of head-out plethysmography chamber, measurement of breathing, data analysis, prepared manuscript C_LIO_LIKyle Kentch: development of head-out plethysmography chamber, programmed software to collect and analyze data, prepared manuscript C_LIO_LIJason Kronenfeld: development of tools to analyze data, analysis of data C_LIO_LIBenjamin Renquist: development of head-out plethysmography chamber, statistical analysis, prepared manuscript C_LI
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Stiffening of the Extracellular Matrix is a Sufficient Condition for AirwayHyperreactivity. 91%
- Sulforhodamine B and exogenous surfactant effects on alveolar surface tension under acute respiratory distress syndrome conditions 90%
- Prenatal cannabinoid exposure affects central cardiorespiratory control in young male and female rats 89%
Similar papers in this journal
- An automated morphometric approach to evaluate distal lung patterning in mouse models of Bronchopulmonary Dysplasia 94%
- PVP1–The People’s Ventilator Project: A fully open, low-cost, pressure-controlled ventilator 94%
- Serum Amyloid P inhibits single stranded RNA-induced lung inflammation, lung damage, and cytokine storm in mice 91%
Similar papers in this journal
- Postinspiratory complex acts as a gating mechanism regulating swallow-breathing coordination and other laryngeal behaviors 92%
- Mapping responses to focal injections of bicuculline in the lateral parafacial region identifies core regions for maximal generation of active expiration 92%
- Effect of chronic JUUL aerosol inhalation on inflammatory states of the brain, lung, heart and colon in mice 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.