Back

mrHARDIflow : A pipeline tailored for the preprocessing and analysis of Multi-Resolution High Angular diffusion MRI and its application to a variability study of the PRIME-DE database

Valcourt Caron, A.; Shmuel, A.; Hao, Z.; Descoteaux, M.

2021-11-23 neuroscience
10.1101/2021.11.22.469616 bioRxiv
Show abstract

The validation of advanced methods in diffusion MRI requires finer acquisition resolutions, which is hard to acquire with decent Signal-to-Noise Ratio (SNR) in humans. The use of Non-Human Primates (NHP) and anaesthesia is key to unlock valid microstructural maps, but tools must be adapted and configured finely for them to work well. Here, we propose a novel processing pipeline implemented in Nextflow, designed for robustness and scalability, in a modular fashion to allow for maintainability and a high level of customization and parametrization, tailored for the analysis of diffusion data acquired on multiple spatial resolutions. Modules of processes and workflows were implemented upon cutting edge and state-of-the-art MRI processing technologies and diffusion modelling algorithms, namely Diffusion Tensor Imaging (DTI), Constrained Spherical Deconvolution (CSD) and DIstribution of Anisotropic MicrOstructural eNvironments in Diffusion-compartment imaging (DIAMOND), a multi-tensor distribution estimator. Using our pipeline, we provide an in-depth study of the variability of diffusion models and measurements computed on 32 subjects from 3 sites of the PRIME-DE, a database containing anatomical (T1, T2), functional (fMRI) and diffusion (DWI) imaging of Non-Human Primate (NHP). Together, they offer images acquired over a range of different spatial resolutions, using single-shell and multi-shell b-value gradient samplings, on multiple scanner vendors, that present artifacts at different level of importance. We also perform a reproducibility study of DTI, CSD and DIAMOND measurements outputed by the pipeline, using the Aix-Marseilles site, to ensure our implementation has minimal impact on their variability. We observe very high reproducibility from a majority of diffusion measurements, only gamma distribution parameters computed on the DIAMOND model display a less reproducible behaviour. This should be taken into consideration when future applications are performed. We also show that even if promising, the PRIME-DE diffusion data exhibits a great level of variability and its usage should be done with care to prevent instilling uncertainty in statistical analyses.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.