Integration of a radiofrequency coil and commercial field camera for ultra-high-field MRI
Gilbert, K. M.; Dubovan, P.; Gati, J. S.; Menon, R. S.; Baron, C. A.
Show abstract
PurposeTo develop an RF coil with an integrated commercial field camera for ultra-high field (7 T) neuroimaging. The RF coil will operate within a head-only gradient coil and be subject to the corresponding design constraints. The RF coil can thereafter be used for subject-specific correction of k-space trajectories--notably in gradient-sensitive sequences such as single-shot spiral imaging. MethodsThe transmit and receive performance was evaluated before and after the integration of field probes, while field probes were evaluated when in an optimal configuration external to the coil and after their integration. Diffusion-weighted EPI and single-shot spiral acquisitions were employed to evaluate the efficacy of correcting higher order field perturbations and the consequent effect on image quality. ResultsField probes had a negligible effect on RF-coil performance, including the transmit efficiency, transmit uniformity, and mean SNR over the brain. Modest reductions in field-probe signal lifetimes were observed, caused primarily by non-idealities in the gradient and shim fields of the head-only gradient coil at the probe positions. The field monitoring system could correct up to second-order field perturbations in single-shot spiral imaging. ConclusionThe integrated RF coil and field camera was capable of concurrent field monitoring within a 7T head-only scanner and facilitated the subsequent correction of k-space trajectories during spiral imaging.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- RF shimming strategy for an open 60-channel RF transmit 7T head coil for routine use on the single transmit mode 98%
- SNR-Efficient Whole-Brain Pseudo-Continuous Arterial Spin Labeling Perfusion Imaging at 7 Tesla 97%
- Vendor-neutral sequences (VENUS) and fully transparent workflows improve inter-vendor reproducibility of quantitative MRI 97%
Similar papers in this journal
Similar papers in this journal
- Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas 96%
- An in-vivo study of BOLD laminar responses as a function of echo time and static magnetic field strength 95%
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 94%
Similar papers in this journal
- Increased brain coverage and efficiency when measuring current-induced magnetic fields by use of simultaneous multi-slice echo-planar MRI 94%
- Sub-millimetre resolution laminar fMRI using Arterial Spin Labelling in humans at 7T 94%
- Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.