Closed-Loop Control of Anesthetic State in Non-Human Primates
Chakravarty, S.; Donoghue, J. A.; Waite, A. S.; Mahnke, M.; Garwood, I. C.; Miller, E. K.; Brown, E. N.
Show abstract
Continuous monitoring of electroencephalogram (EEG) recordings in humans under general anesthesia (GA) has demonstrated that changes in EEG dynamics induced by an anesthetic drug are reliably associated with the altered arousal states caused by the drug. This observation suggests that an intelligent, closed-loop anesthesia delivery (CLAD) system operating in real-time could track EEG dynamics and control the infusion rate of a programmable pump to precisely maintain unconsciousness. The United States FDA acknowledges the potential benefits of such automatic physiological closed-loop control devices for patient care. Bringing these devices into clinical practice requires establishing their feasibility in suitable animal models. Therefore, given the close neurophysiological proximity between human and non-human primates (NHPs), we address this problem by developing and validating a propofol CLAD system in rhesus macaques. Our CLAD system has three key components: (1) a data acquisition system that records cortical local field potentials (LFPs) from an NHP in real-time; (2) a computer executing our CLAD algorithm that takes in the LFP signals as input and outputs infusion rates; and (3) a computer-controlled infusion pump that administers intravenous propofol. Our CLAD system controls an empirically-determined LFP marker of unconsciousness (MOU) at a user-prescribed target value by updating every 20 seconds the propofol infusion rate based on real-time processing of the LFP signal. The MOU is the instantaneous power in the 20 to 30 Hz band of the LFP spectrogram. Every cycle (duration{approx} 20 sec), our CLAD algorithm updates the MOU estimate and uses a robust optimal control strategy to adjust the propofol infusion rate based on the instantaneous error. This error is computed as the difference between the current and the user-prescribed target MOU values. Using neural recordings from multiple NHP anesthesia sessions, we first established that our chosen MOU signal was strongly correlated with propofol-induced decreased spiking activity which itself has been shown earlier to be associated with the level of unconsciousness in NHPs. Then we designed robust optimal control strategies that used subject-specific pharmacokinetic-pharmacodynamic models describing the MOU dynamics due to propofol infusion rate changes. Finally, we achieved safe and efficient closed-loop control of level of unconsciousness in 9 CLAD experiments involving 2 NHPs and 2 different 125 min long target MOU profiles with three target MOU changes within a given experiment. Our CLAD system performs stably, accurately and robustly across a total of 1125 min of closed-loop control. The CLAD performance measures, represented as median (25th percentile, 75th percentile), are 3.13 % (2.62%, 3.53%) for inaccuracy, 0.54 %(-0.31%, 0.89%) for bias, -0.02%/min (-0.06%/min, 0.00%/min) for divergence, and 3% (2.49%, 3.59%) for wobble. These performance measures were comparable or superior to previously reported CLAD performance measures from clinical studies (conducted outside USA) as well as rodent-based studies. The key innovations here are: (1) a pre-clinical NHP model for CLAD development and testing, (2) a neuroscience-informed LFP-based MOU for CLAD, (3) parsimonious, pharmacology-informed models to describe MOU dynamics under propofol infusion in rhesus macaques, (4) a novel numerical testing framework for propofol CLAD that incorporates a principled optimal robust control strategy for titrating propofol, and finally (5) experimental findings demonstrating the feasibility of stable, accurate and robust CLAD in the NHP model. Our NHP-based CLAD framework provides a principled pre-clinical research platform that can form the foundation for future clinical studies.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Average beta burst duration profiles provide a signature of dynamical changes between the ON and OFF medication states in Parkinson's disease 95%
- A hidden Markov model reliably characterizes ketamine-induced spectral dynamics in macaque LFP and human EEG 94%
- Chemotherapy-Induced Cachexia and Model-Informed Dosing to Preserve Lean Mass in Cancer Treatment 93%
Similar papers in this journal
- Quantitative assessment of the relationship between behavioral and autonomic dynamics during propofol-induced unconsciousness 94%
- A 3D brain unit model to further improve prediction of local drug distribution within the brain 94%
- Computational simulation to assess patient safety of uncompensated COVID-19 two-patient ventilator sharing using the Pulse Physiology Engine 93%
Similar papers in this journal
- Deep brain stimulation pulse sequences to optimally modulate frequency-specific neural activity 94%
- Xenon and nitrous oxide induced changes in resting EEG activity can be explained by systematic increases in the relaxation rates of stochastically driven alpha band oscillatory activity 93%
- Improved alpha-beta power reduction via combined Electrical and Ultrasonic stimulation in a Parkinsonian Cortex-Basal Ganglia-Thalamus Computational Model 93%
Similar papers in this journal
- Optimization of an unscented Kalman filter for an embedded platform 93%
- Quantifiable identification of flow-limited ventilator dyssynchrony with the deformed lung ventilator model 93%
- Comparing physiological impacts of positive pressure ventilation versus self-breathing via a versatile cardiopulmonary model incorporating a novel alveoli opening mechanism 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.