Development of a label-free microfluidic impedimetric immunoassay for anti-SPAG16 antibody.
Froyen, T.; Vreys, F.; Thoelen, R.; Slaets, L.; Somers, V.
Show abstract
A recently found biomarker regarding multiple sclerosis, namely the anti-SPAG16 antibody (Ab), could be a potential way for early detection, prognosis and diagnosis of said autoimmune disease. Merging electrochemical analysis with a microfluidic system is a novel approach, which avoids the use of labelling steps as seen in traditional ELISA immunoassays. In this study, aluminium interdigitated electrodes on polystyrene-coated PET foils were implemented in a microfluidic flow cell to bind and detect SPAG16 Abs by impedimetric measurements. The coated PET foils showed a clear affinity for the fusion protein SPAG16-THIO and thioredoxin (THIO). Determining sensitivity and specificity of antibody-antigen binding using a microfluidic ELISA immunoassay has revealed the test to be unreliable by showing no linear pattern of a dilution series of the standard and producing skewed inconsistent results. The impedimetric analysis showed opposite results of what one would expect. The systems efficiency is in need to be revised and optimised before undergoing actual diagnostic tests. Further advancement could be done by reducing leakage, securing a more stable entrance for injection and circumventing the occurence of air bubbles in the wells. SAMENVATTINGMultiple sclerosis (MS) is een auto-immune ziekte, gekenmerkt door inflammatie van het centraal zenuwstelsel en demyelinisatie van axonen. Een recent gevonden proteine, namelijk het anti-SPAG16 antilichaam, is bewezen een biomerker te zijn voor MS. Met behulp van een elektrochemisch analytisch systeem gecombineerd met microfluidica zou men anti-SPAG16 antilichamen kunnen opsporen voor vroegtijdige detectie, prognose en diagnose. Het grote voordeel tegenover traditionele ELISA testen is het elimineren van labelling stappen waardoor de immunoassay goedkoper en gebruiksvriendelijk wordt. In deze studie werden overlappende aluminium elektrodes op polystyreen-gecoate PET-plaatjes geimplementeerd in een microfluidische flow cell voor binding en detectie van anti-SPAG16 antilichamen door middel van impedimetrische metingen. De gecoate PET-plaatjes vertonen een duidelijke affiniteit voor 0,1 g/ml SPAG16 en THIO. Het bepalen van sensitiviteit en specificiteit van antilichaam-antigen binding, gebruikmakende van een ELISA immunoassays, gaf aan dat de test onbetrouwbaar is doordat geen duidelijk patroon voor standaardoplossingen zichtbaar was en resultaten vertekend en inconsistent bleken te zijn. De impedimetrische analyse vertoonde tevens onbetrouwbare resultaten, waarbij een omgekeerd effect werd geobserveerd van wat er in theorie zou moeten gebeuren. De efficientie van het systeem moet herzien en geoptimaliseerd worden voordat men het voor diagnostische testen kan gebruiken. Verdere vorderingen zouden gerealiseerd kunnen worden door lekkages te reduceren, steviger bevestigen van de PDMS-ingang en de ontwikkeling van luchtbellen in de wells te vermijden.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Functionalized TiO2 nanotube-based Electrochemical Biosensor for Rapid Detection of SARS-CoV-2 94%
- Absolute quantitation of serum antibody reactivity using the Richards growth model for antigen microspot titration 93%
- CovidArray: a microarray-based assay with high sensitivity for the detection of SARS-CoV-2 in nasopharyngeal swabs 92%
Similar papers in this journal
- Electrical Readout Strategies of GFET Biosensors for Real-World Requirements 95%
- Electrochemical detection of myeloperoxidase (MPO) in blood plasma with surface-modified electroless nickel immersion gold (ENIG) printed circuit board (PCB) electrodes 95%
- A Mem-dELISA platform for dual color and ultrasensitive digital detection of colocalized proteins on extracellular vesicles 94%
Similar papers in this journal
- FluidFM as a Tool to Study Adhesion Forces of Bacteria - Optimization of Parameters and Comparison to Conventional Bacterial Probe Scanning Force Spectroscopy 95%
- A low-cost smart system for electrophoresis-based nucleic acids detection at the visible spectrum 94%
- Analytical performance of 17 commercially available point-of-care tests for CRP to support patient management at lower levels of the health system 94%
Similar papers in this journal
- High-throughput bacterial aggregation analysis in droplets 95%
- Optical tuning of polymer functionalized zinc oxide quantum dots as a selective probe for specific detection of antibiotics 93%
- A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide 93%
Similar papers in this journal
- Point-of-care detection of SARS-CoV-2 in nasopharyngeal swab samples using an integrated smartphone-based centrifugal microfluidic platform 94%
- Artificial Intelligence Performance in Testing Microfluidics for Point-of-Care 94%
- Microfluidic device combining hydrodynamic and dielectrophoretic trapping for the controlled contact between single micro-sized objects and application to adhesion assays 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.