Experimental Investigation Of Pulse Sterilization Of Viral Infection

Chumakov, V. I.; Ostryzhny, M.; Kharchenko, O.; Naumenko, K.; Zagorodnya, S.; Muraveinyk, V.; Tarasevich, A.

2020-12-16 bioengineering
10.1101/2020.12.16.423002 bioRxiv
Show abstract

The results of experimental investigations of the effect of high-intensity pulsed UV radiation on the influenza virus type A (H1N1) are presented. The research methodology is developed and the structure of the experiments is described. An end-face plasma accelerator was used as a radiation source, which provides a power pulsed discharge in an open atmosphere. The high efficiency of inactivation of the infectiousness of the virus was shown within a short period of time. The possibility of providing urgent 100% sterilization of a viral infection has been shown for the first time. A model for calculating the efficiency of pulse sterilization has been developed. The prospects for the application of pulse sterilization technology to combat coronavirus infection are considered.