Early detection of physiological deterioration in post-surgical patients using wearable technology combined with an integrated monitoring system: a pre- and post-interventional study
Watkinson, P. J.; Pimentel, M.; Clifton, L.; Clifton, D.; Vollam, S.; Young, D.; Tarassenko, L.
Show abstract
ObjectivesLate recognition of physiological deterioration is a frequent problem in hospital wards. We assessed whether ambulatory (wearable) physiological monitoring combined with a system that continuously merges physiological variables into a single "risk" score (VSI), changed care and outcome in patients after major surgery. DesignPre- and post-interventional study. SettingA single centre tertiary referral university hospital upper-gastrointestinal service. ParticipantsPatients who underwent major upper-gastrointestinal surgery. InterventionsPhase-I (pre-intervention phase): Patients received continuous wearable monitoring and standard care, but the VSI score was not available for clinical use. Phase-II (post-intervention phase): Patients received continuous wearable monitoring. In addition to standard care the VSI score was displayed for use in clinical practice. Measurements and Main Results200 participants were monitored in phase-I. 207 participants were monitored in phase-II. Participants were monitored (median, interquartile range, IQR) for 30.2% (13.8-49.2) of available time in phase-I and 58.2% (33.1-75.2) of available time in phase-II. Clinical staff recorded observations more frequently in the 36 hours prior to a major adverse event (death, cardiac arrest or unplanned admission to intensive care) for phase-II participants (median, IQR, time between observations of 1.00, 0.50-2.08 hours) than phase-I participants (1.50, 0.75-2.50 hours, p<0.001). There was no difference in observation frequency between the two phases for participants who did not undergo an adverse event (p=0.129). 6/200 participants died before hospital discharge in phase-I, 1/207 participants died in hospital in phase-II. 20 (10.0%) patients in phase-I and 26 (12.6%) patients in phase-II had an unplanned admission to intensive care. Ward length-of-stay was unaltered (8.91, 6.71-14.02 days in phase-I, vs. 8.97, 5.99-13.85 days in phase-II, p=0.327). ConclusionThe combination of the integrated monitoring system with ambulatory monitoring in high-risk post-surgical patients improved recognition and management of deteriorating patients without increasing the observation rate in those patients who did not deteriorate.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Electronic early notification of sepsis in hospitalized ward patients: a study protocol for a stepped-wedge cluster randomized controlled trial 96%
- Statistical Analysis Plan for the Stepped-wedge Cluster Randomized Controlled Trial of Electronic Early Notification of Sepsis in Hospitalized Ward Patients (SCREEN): a study protocol for a stepped-wedge cluster randomized controlled trial 96%
- Decision support system to evaluate VENTilation in the Acute Respiratory Distress Syndrome (DeVENT study) – Trial Protocol 95%
Similar papers in this journal
- Derivation and validation of a triage tool for acutely ill adults with suspected COVID-19: The PRIEST observational cohort study 95%
- Triaging and Referring In Adjacent General and Emergency Departments (the TRIAGE trial): a cluster randomised controlled trial 94%
- Randomised, controlled, feasibility trial comparing vasopressor infusion administered via peripheral cannula versus central venous catheter for critically ill adults: a study protocol 94%
Similar papers in this journal
- The clinical, humanistic, and economic outcomes, including experiencing of patient safety events, associated with admitting patients to single rooms compared with shared accommodation for acute hospital admissions. A narrative synthesis systematic literature review 94%
- Development and validation of automated computer aided-risk score for predicting the risk of in-hospital mortality using first electronically recorded blood test results and vital signs for COVID-19 hospital admissions: a retrospective development and validation study 94%
- Performance of digital Early Warning Score (NEWS2) in a cardiac specialist setting: retrospective cohort study 94%
Similar papers in this journal
- A comprehensive ML-based Respiratory Monitoring System for Physiological Monitoring & Resource Planning in the ICU 91%
- Quantifying Sleep-Wake Rhythms in the Hospital Environment with Digital Technologies 91%
- Bridging the Literacy Gap for Surgical Consents: An AI-Human Expert Collaborative Approach 91%
Similar papers in this journal
- Scientific hypothesis generation process in clinical research: a secondary data analytic tool versus experience study protocol 91%
- Strategies and Tools for electronic health records and physician workflow alignment: A scoping review protocol 91%
- Use of digital technology tools to examine patient adherence to a prescription omega-3 polyunsaturated acids therapy intended to mitigate cardiovascular risk: protocol and preliminary demographic data from the DIAPAsOn prospective observational study 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.