Personalization of mathematical models of human atrial action potential
Pikunov, A. V.; Syunyaev, R. A.; Steckmeister, V.; Kutschka, I.; Voigt, N.; Efimov, I. R.
Show abstract
Atrial cardiomyocytes demonstrate a wide spectrum of patient-specific, tissue-specific, and pathology-specific action potential (AP) phenotypes due to differences in protein expression and posttranslational modifications. Accurate simulation of the AP excitation and propagation in healthy or diseased atria requires a mathematical model capable of reproducing all the differences by parameter rescaling. In the present study, we have benchmarked two widely used electrophysiological models of the human atrium: the Maleckar and the Grandi models. In particular, patch-clamp AP recordings from human atrial myocytes were fitted by the genetic algorithm (GA) to test the models' versatility. We have shown that the Maleckar model results in a more accurate fitting of heart rate dependence of action potential duration (APD) and resting potential (RP). On the other hand, both models demonstrate the poor fitting of the plateau phase and spike-and-dome morphologies. We propose that modifications to L-type calcium current-voltage relationships are required to improve atrial models' fidelity.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A Reproducible Protocol to Assess Arrhythmia Vulnerability in Silico: Pacing at the End of the Effective Refractory Period 97%
- Atrioventricular nodal reentrant tachycardia onset,sustainability, and spontaneous termination in rabbit atrioventricular node model with autonomic nervous system control 96%
- Sensitivity and uncertainty analysis of two human atrial cardiac cell models using Gaussian process emulators 96%
Similar papers in this journal
- Reciprocal interaction between IK1 and If in biological pacemakers: A simulation study 95%
- Arrhythmia Mechanisms and Spontaneous Calcium Release: II - From Calcium Spark to Re-entry and Back 95%
- HippoUnit: A software tool for the automated testing and systematic comparison of detailed models of hippocampal neurons based on electrophysiological data 93%
Similar papers in this journal
- Transmural and rate-dependent profiling of drug-induced arrhythmogenic risks through in silico simulations of multichannel pharmacology 96%
- Detection and categorization of severe cardiac disorders based solely on pulse interval measurements 95%
- Phenomenological models of NaV1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms. 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.