Arterial blood contrast (ABC) enabled by magnetization transfer (MT): a novel MRI technique for enhancing the measurement of brain activation changes
Schulz, J.; Fazal, Z.; Metere, R.; Marques, J.; Norris, D.
Show abstract
Functional brain imaging in humans is almost exclusively performed using blood oxygenation level dependent (BOLD) contrast. This typically requires a period of tens of milliseconds after excitation of the spin system to achieve maximum contrast, leading to inefficient use of acquisition time, reduced image quality, and inhomogeneous sensitivity throughout the cortex. We utilise magnetisation transfer to suppress the signal differentially from grey matter relative to blood so that the local increase in blood volume associated with brain activation (mainly occurring in the arterioles and capillaries) will increase the measured signal. Arterial blood contrast (ABC) is additive to the residual BOLD effect, but will have its maximum value at the time of excitation. We measured brain activation using combined ABC and residual BOLD contrast at different times post-excitation and compared this to BOLD data acquired under otherwise identical conditions. We conclude that using ABC and measuring shortly after excitation gives comparable sensitivity to standard BOLD but will provide greater efficiency, spatial specificity, improved image quality, and lower inter-subject variability. ABC offers new perspectives for performing functional MRI.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- T1234: A distortion-matched structural scan solution to misregistration of high resolution fMRI data 97%
- A 3T investigation of B1+-inhomogeneity tolerance in MP2RAGE-based R1-mapping by calculating second contrast that permits previously problematic sequence parameters 96%
- A characterization of cardiac-induced noise in R2* maps of the brain 96%
Similar papers in this journal
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI 96%
- MESMERISED: Super-accelerating T1 relaxometry and diffusion MRI with STEAM at 7 T for quantitative multi-contrast and diffusion imaging 96%
- Medullary vein architecture modulates the white matter BOLD cerebrovascular reactivity signal response to CO2: observations from high-resolution T2* weighted imaging at 7T 96%
Similar papers in this journal
- Denoising physiological data collected during multi-band, multi-echo EPI sequences 96%
- Longitudinal deformation based morphometry pipeline to study neuroanatomical differences in structural MRI based on SyN unbiased templates 94%
- An open, fully-processed data resource for studying mood and sleep variability in the developing brain 94%
Similar papers in this journal
- Characterization and Mitigation of a Simultaneous Multi-Slice fMRI Artifact: Multiband Artifact Regression in Simultaneous Slices 98%
- Assessing methods for geometric distortion compensation in 7T gradient echo fMRI data 96%
- A novel approach for assessing hypoperfusion in stroke using spatial independent component analysis of resting-state fMRI data 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.