An acceptable method to evaluate the analytical performance of real-time fluorescent RT-PCR targeting SARS-CoV-2
Ren, X.-d.; Tang, Q.-M.; Chen, M.; Huang, Q.; Huang, H.-L.; Wang, L.; Su, N.; Sun, X.-G.; Wei, K.; Lu, W.-P.; Deng, S.-L.; Huang, Q.
Show abstract
It was necessary to carry out methodologies evaluations of real-time fluorescent reverse-transcription PCR (RT-PCR) targeting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Considering biosafety issues and lack of positive specimens in some special locations in China, the routine specimens from healthy individuals were used to perform methodologies evaluations, in which the indexes were the differences of quantification cycle values ({Delta} Cq) between human derived internal reference control (IRC) genes of a specimen and quality control (QC). Serial experiments were carried out to evaluate various factors that might affect aforementioned methodologies, such as types of virus transport mediums, methods of specimen pretreatment and template preparation, specimen vortex strength, specimen storage temperature and duration. The results showed that using {Delta}Cq values as indexes, among various factors that might affect analytical performance, it was better to store specimens in the normal saline transport mediums, inactivate pathogens using water or metal bath, release more virus particles from swabs by vortex mixing, extract nucleic acids with centrifuge methods, and perform amplification assays timely. Aforementioned opinions and optimum conditions were further confirmed by SRAS-CoV-2 pseudovirus and clinical positive specimens. Altogether, the results of this study indicated that the routine specimens from healthy individuals could be used to evaluate the analytical performance of real-time fluorescent RT-PCR targeting SRAS-CoV-2, of which the indexes were the {Delta}Cq values between IRC genes of a specimen and QC. This acceptable method was extremely valuable in both theoretical and practical significance under current pandemic of coronavirus disease 2019 (COVID-19).
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Sensitivity evaluation of 2019 novel coronavirus (SARS-CoV-2) RT-PCR detection kits and strategy to reduce false negative 96%
- Validation of a new automated chemiluminescent anti-SARS-CoV-2 IgM and IgG antibody assay system detecting both N and S proteins in Japan 96%
- Development and Evaluation of AccuPower® COVID-19 Multiplex Real-Time RT-PCR Kit and AccuPower® SARS-CoV-2 Multiplex Real-Time RT-PCR Kit for SARS-CoV-2 Detection in Sputum, NPS/OPS, Saliva and Pooled Samples 95%
Similar papers in this journal
- Analysis of external quality assessment samples revealed crucial performance differences between commercial RT-PCR assays for SARS-CoV-2 detection when taking extraction methods and real-time-PCR instruments into account 94%
- Comparison of three TaqMan Real-Time Reverse Transcription-PCR assays in detecting SARS-CoV-2 94%
- Diagnostic comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies 93%
Similar papers in this journal
- Evaluation the auxiliary diagnosis value of antibodies assays for detection of novel coronavirus (SARS-Cov-2) causing an outbreak of pneumonia (COVID-19) 95%
- Evaluation of seven different rapid methods for nucleic acid detection of SARS-COV-2 virus 95%
- Amplification of human β-glucoronidase gene for appraising the accuracy of negative SARS-CoV-2 RT-PCR results in upper respiratory tract specimens 94%
Similar papers in this journal
- Evaluation of nCoV-QS (MiCo BioMed) for RT-qPCR detection of SARS-CoV-2 from nasopharyngeal samples using CDC FDA EUA qPCR kit as a gold standard: an example of the need of validation studies. 94%
- Evaluation of three rapid lateral flow antigen detection tests for the diagnosis of SARS-CoV-2 infection 94%
- Pushing beyond specifications: Evaluation of linearity and clinical performance of a fully automated SARS-CoV-2 RT-PCR assay for reliable quantification in blood and other materials outside recommendations 93%
Similar papers in this journal
- Development and validation of cost-effective one-step multiplex RT-PCR assay for detecting the SARS-CoV-2 infection using SYBR Green melting curve analysis 95%
- A Paper-based Loop-Mediated Isothermal Amplification (LAMP) Assay for Highly Pathogenic Avian Influenza 94%
- A new system in qualitative RT-PCR detecting SARS-CoV-2 in biological samples: an Italian experience. 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.