Variation in Aerosol Production Across Oxygen Delivery Devices in Spontaneously Breathing Human Subjects
Iwashyna, T. J.; Boehman, A.; Capelcelatro, J.; Cohn, A. M.; Cooke, J. M.; Costa, D. K.; Eakin, R. M.; Prescott, H. C.; Woolridge, M. S.
Show abstract
We sought to assess whether HHFNC results in greater production of aerosolized particles than 6 liters per minute nasal cannula, using state-of-the-art techniques of aerosol measurement, in spontaneously breathing human volunteers in a simulated hospital room. For each volunteer, we first measured background aerosol levels in the room immediately prior to testing. We then measured aerosol levels while the healthy volunteer laid in bed - - with the head of bed at 30 degrees - - wearing the following oxygen delivery devices: (a) 6L/min nasal canula (NC) with humidification; (b) non-re-breather mask (NRB) with 15L/min gas flow, non-humidified; (c) HHFNC with 30L/min gas flow; (d) HHFNC with 60L/min gas flow. Two scanning mobility particle sizing (SMPS) systems (TSI 3080/3030, TSI 3080/3750) were used to measure aerosols 10 to 500 nanometer (nm) in size for each of the oxygen delivery devices. There was no variation in aerosol level within patients between room air, 6 L/min NC, 15 L/min NRB, 30 L/min HHFNC, and 60 L/min HHFNC, regardless of coughing.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A simple, effective enclosure with disposable coverings for inexpensive containment of aerosolized COVID viruses during tracheal intubation and extubation 96%
- The new silicone N99 half-piece respirator, VJR-NMU N99: A novel and effective tool to prevent COVID-19 95%
- N95 respirators, disposable procedure masks and reusable cloth face coverings: total inward leakage and filtration efficiency of materials against aerosol 95%
Similar papers in this journal
- Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking 95%
- Comparison of three air samplers for the collection of four nebulized respiratory viruses 92%
- Effective design of barrier enclosure to contain aerosol emissions from COVID-19 patients 92%
Similar papers in this journal
- Spatiotemporal droplet dispersion measurements demonstrate face masks reduce risks from singing: results from the COvid aNd FacEmaSkS Study (CONFESS) 94%
- Aerosol emission rates from playing wind instruments – Implications for COVID-19 transmission during music performance 93%
- Clinical characterization of respiratory droplet production during common airway procedures using high-speed imaging 93%
Similar papers in this journal
- Computational simulations of hyoid bone position and tracheal displacement: Effects on upper airway patency and tissue mechanics 91%
- Hyoid bone position and upper airway patency: A computational finite element modeling study 91%
- Sulforhodamine B and exogenous surfactant effects on alveolar surface tension under acute respiratory distress syndrome conditions 89%
Similar papers in this journal
- Evaluation of High Flow Local Extraction on control of the aerosol plume in an operating theatre 96%
- Measurement of small droplet aerosol concentrations in public spaces using handheld particle counters 93%
- Eulerian-Lagrangian and thin film modeling of drug delivery under physiologically varying breathing in a realistic lung model 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.