Novel software for automated morphometric analysis of stented arteries
Resnick, A.; Hooshdaran, B.; Pressly, B. B.; Guerrero, D. T.; Alferiev, I. S.; Chorny, M.; Levy, R. J.; Fishbein, I.
Show abstract
Morphometric analysis of explanted arteries remains the gold standard in assessing pathological mechanisms of arterial disease, and the efficacy of therapeutic interventions. Software currently used for morphometric analysis (ImageJ, ImagePro, etc.) requires manual tracing of each region of interest by the user to obtain direct and derived data needed for analysis. Manual segmentation of borders between differently stained arterial compartments is time-consuming and prone to bias, even when the operator is blind to the treatment type. Here, we report newly designed morphometric software, floodSeg, which greatly aids analysis through semiautomated segmentation, followed by automated computation and data entry. The program includes tools for both rapid component selection, and precision user-controlled contour correction. In practice, segmentation occurs following the selection of seed points and corresponding threshold values, for each desired component. The flood fill algorithm is used to map out components, followed by Sklanskys convex-hull algorithm to obtain the outer contours. If necessary, convexity defects can be overcome through manual point placement on top of existing points, and regeneration of the contour. floodSeg was tested using a set of non-uniformly stained stented rat arteries, and compared against manually obtained results. The accuracy of the resulting measurements was within the expected limit based on repeated manual measurements by the same operator, and did not exceed 3%. Most notably, the duration for data acquisition using floodSeg was less than 20% of the time required for manual measurements by an experienced operator. Thus, our contribution is an improvement on widely used software, with significant potential for application in a multitude of areas of pathology practice.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Full-field optical coherence tomography for the diagnosis of giant cell arteritis 96%
- Development of a Novel Index to Characterise Arterial Dynamics Using Ultrasound Imaging 95%
- In vivo recellularization of xenogeneic vascular grafts decellularized with high hydrostatic pressure method in a porcine carotid arterial interpose model 94%
Similar papers in this journal
- Analysis of vascular architecture and parenchymal damage generated by reduced blood perfusion in decellularized porcine kidneys using a gray level co-occurrence matrix 96%
- Deep learning-based end-to-end automated stenosis classification and localization on catheter coronary angiography 95%
- Fairness in Cardiac Magnetic Resonance Imaging: Assessing sex and racial bias in deep learning-based segmentation 92%
Similar papers in this journal
- Automated IntraVascular UltraSound Image Processing and Quantification of Coronary Artery Anomalies: The AIVUS-CAA software 94%
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model 93%
- Digitizing ECG image: new fully automated method and open-source software code 92%
Similar papers in this journal
- Biomechanical Characterization Of Porcine Lower Limb Arteries For Preclinical Evaluation Of Peripheral Vascular Devices 94%
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 94%
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.