Serum cytokine levels are modulated by specific frequencies, amplitudes, and pulse widths of vagus nerve stimulation
Tsaava, T.; Datta-Chaudhuri, T.; Addorisio, M. E.; Masi, E. B.; Silverman, H. A.; Newman, J. E.; Imperato, G. H.; Bouton, C. E.; Tracey, K. J.; Chavan, S. S.; Chang, E. H.
Show abstract
Electrical stimulation of peripheral nerves is a widely used technique to treat a variety of conditions including chronic pain, motor impairment, headaches, and epilepsy. Nerve stimulation to achieve efficacious symptomatic relief depends on the proper selection of electrical stimulation parameters to recruit the appropriate fibers within a nerve. Recently, electrical stimulation of the vagus nerve has shown promise for controlling inflammation and clinical trials have demonstrated efficacy for the treatment of inflammatory disorders. This application of vagus nerve stimulation activates the inflammatory reflex, reducing levels of inflammatory cytokines during inflammation. Here, we wanted to test whether altering the parameters of electrical vagus nerve stimulation would change circulating cytokine levels of normal healthy animals in the absence of increased inflammation. To examine this, we systematically tested a set of electrical stimulation parameters and measured serum cytokine levels in healthy mice. Surprisingly, we found that specific combinations of pulse width, pulse amplitude, and frequency produced significant increases of the pro-inflammatory cytokine tumor necrosis factor alpha (TNF), while other parameters selectively lowered serum TNF levels, as compared to sham-stimulated mice. In addition, serum levels of the anti-inflammatory cytokine interleukin-10 (IL-10) were significantly increased by select parameters of electrical stimulation but remained unchanged with others. These results indicate that electrical stimulation parameter selection is critically important for the modulation of cytokines via the cervical vagus nerve and that specific cytokines can be increased by electrical stimulation in the absence of inflammation. As the next generation of bioelectronic therapies and devices are developed to capitalize on the neural regulation of inflammation, the selection of nerve stimulation parameters will be a critically important variable for achieving cytokine-specific changes.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Positive Rate Dependent Action Potential Prolongation By Modulating Potassium Ion Channels 89%
- Galanin inhibits visceral afferent responses to noxious mechanical and inflammatory stimuli 88%
- Multichannel Modulation of Depolarizing and Repolarizing Ion Currents Increases the Positive Rate Dependence of Action Potential Prolongation 88%
Similar papers in this journal
- Selective stimulation of the ferret abdominal vagus nerve with multi-contact nerve cuff electrodes 93%
- Multi-channel intraneural vagus nerve recordings with a novel high-density carbon fiber microelectrode array 92%
- Evaluating phasic transcutaneous vagus nerve stimulation (taVNS) with pupil dilation: the importance of stimulation intensity and sensory perception 91%
Similar papers in this journal
- Pruriception and neuronal coding in nociceptor subtypes in human and nonhuman primates 92%
- Perceptual responses to microstimulation frequency are spatially organized in human somatosensory cortex 91%
- Postinspiratory complex acts as a gating mechanism regulating swallow-breathing coordination and other laryngeal behaviors 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.