Back

Contrast-Enhanced, Molecular Imaging of Vascular Inflammation in the Mouse Model by Simultaneous PET/MRI

Du, S.; Ng, T.; House, A.; Tang, T.; Zheng, L.; Tu, C.; Peake, J.; Espiritu, I.; Ma, K.-L.; Pinkerton, K.; Jacobs, R.; Louie, A.

2019-12-17 bioengineering
10.1101/2019.12.16.878652 bioRxiv
Show abstract

Despite advances in diagnosis and management, cardiovascular diseases (CVDs) remain the leading cause of death in the US. Atherosclerosis is the most common form of CVD and the vulnerability of atherosclerotic plaques to rupture is a primary determinant for risk of catastrophic ischemic events. Current imaging of atherosclerotic disease focuses on assessing plaque size and the degree of luminal stenosis, which are not good predictors of plaque stability. Functional methods to identify biomarkers of inflammation in plaques could facilitate assessment of plaque instability to allow early intervention. In this study, we validate the use of a purpose-built, magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) insert for multimodal, molecular imaging of vulnerable plaques in mice. We illustrate the application of PET to screen for inflamed regions to guide the application of MRI. Molecular MRI visualizes regions of vascular inflammation and is coupled with anatomical MRI to generate detailed maps of the inflammatory marker within the context of an individual vessel. As a testbed for this imaging methodology, we developed a multimodal, iron oxide nanoparticle (NP) targeting vascular cell adhesion molecule-1 (VCAM-1) for simultaneous PET/MRI of vascular inflammation performed on a mouse carotid ligation model. In vitro cell studies confirmed that the NPs are not cytotoxic to liver cells. In vivo simultaneous PET/MRI imaging identified regions of inflammation. Three-dimensional rendering of the MRI data facilitated high-resolution visualization of patterns of inflammation along the injured vessel. Histology validated the co-localization of the NPs with VCAM-1 expression at sites of induced inflammation. The results of this work validate the utility of the simultaneous PET/MR insert as a research tool for small animals and lays groundwork to further advance the potential clinical utility of integrated imaging systems.

Matching journals

The top 10 journals account for 50% of the predicted probability mass.

1
Scientific Reports
3102 papers in training set
Top 2%
15.0%
2
Photoacoustics
11 papers in training set
Top 0.1%
12.7%
3
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.1%
6.4%
4
Alzheimer's Research & Therapy
52 papers in training set
Top 0.5%
4.0%
5
Theranostics
33 papers in training set
Top 0.4%
2.4%
6
Journal of Cerebral Blood Flow & Metabolism
43 papers in training set
Top 0.2%
2.4%
7
Journal of Biomedical Optics
25 papers in training set
Top 0.3%
1.9%
8
PLOS ONE
4510 papers in training set
Top 51%
1.8%
9
Biomedical Optics Express
84 papers in training set
Top 0.6%
1.7%
10
Arteriosclerosis, Thrombosis, and Vascular Biology
65 papers in training set
Top 1%
1.7%
50% of probability mass above
11
Nature Communications
4913 papers in training set
Top 51%
1.7%
12
Cancer Research
116 papers in training set
Top 2%
1.7%
13
Acta Biomaterialia
85 papers in training set
Top 0.5%
1.7%
14
npj Digital Medicine
97 papers in training set
Top 2%
1.5%
15
Science Translational Medicine
111 papers in training set
Top 3%
1.4%
16
Magnetic Resonance in Medicine
72 papers in training set
Top 0.4%
1.4%
17
Frontiers in Cardiovascular Medicine
49 papers in training set
Top 2%
1.4%
18
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 2%
1.2%
19
eLife
5422 papers in training set
Top 48%
1.2%
20
PLOS Computational Biology
1633 papers in training set
Top 20%
1.1%
21
Biomaterials
78 papers in training set
Top 0.9%
1.0%
22
Journal of Controlled Release
39 papers in training set
Top 0.8%
1.0%
23
Frontiers in Neuroscience
223 papers in training set
Top 6%
1.0%
24
Nature Biomedical Engineering
42 papers in training set
Top 2%
0.9%
25
Bioengineering & Translational Medicine
21 papers in training set
Top 0.7%
0.9%
26
Circulation
66 papers in training set
Top 2%
0.8%
27
Nano Letters
63 papers in training set
Top 2%
0.8%
28
European Journal of Nuclear Medicine and Molecular Imaging
19 papers in training set
Top 0.3%
0.8%
29
Nanoscale
39 papers in training set
Top 0.4%
0.8%
30
Atherosclerosis
29 papers in training set
Top 1%
0.8%