Acquisition Speed versus Spatial Resolution in Ultra-High-Resolution Photon-Counting CT: Phantom Study to Guide Protocol Development
Azimi, N.; Lima, J. A. C.; Pourmorteza, A.
Show abstract
Faster ultrahigh-resolution (UHR) photon-counting CT acquisitions facilitate breath-hold imaging, but identical reconstruction settings may conceal differences in spatial resolution. To assess spatial resolution and depiction of small airways and venous stents across helical UHR acquisition configurations. Stationary wire, airway, and venous-stent phantoms underwent one acquisition per configuration using five configurations on a dual-source scanner at 120 kVp. Reconstructions used 0.2- and 0.4-mm thicknesses, the same sharp kernel, and iterative reconstruction strength 1. We measured the full-width at half-maximum of the slice sensitivity profile (SSP) and spatial frequency at 20% of the modulation transfer function (MTF20). Rank-based F tests with Holm adjustment assessed configuration differences in resolution and variability across slices. Airway detection used a profile contrast-to-noise criterion; stent assessment was qualitative. Calculated acquisition time for 400-mm coverage decreased from 9.80 to 1.30 seconds between the slowest and fastest configurations. At 0.2-mm reconstruction thickness, median SSP increased from 0.316 to 0.496 mm, and median MTF20 decreased from 2.870 to 2.059 lp/mm (both P<.001). Interquartile ranges increased from 0.047 to 0.197 mm for SSP and from 0.256 to 0.654 lp/mm for MTF20 (both variability P<.001). Increasing reconstruction thickness to 0.4 mm increased SSP by a median 0.221 mm across 2459 matched slice-wire measurements (P<.001). At 0.2-mm reconstruction thickness, 0.4- and 0.6-mm lumens with 0.2-mm walls were detected only in the slowest configuration. Faster configurations showed less distinct stent struts and greater adjacent-wall distortion. Faster helical UHR photon-counting CT configurations had poorer spatial resolution despite identical nominal slice thickness. Consistent acquisition and reconstruction settings are important for longitudinal comparisons.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 94%
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 92%
- MyoVision-US: an Artificial Intelligence-Powered Software for Automated Analysis of Skeletal Muscle Ultrasonography 91%
Similar papers in this journal
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 92%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 91%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 90%
Similar papers in this journal
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 95%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 94%
- Deep learning-based auto-segmentation of swallowing and chewing structures 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.