Interpretable Automated Detection and Measurement of Dome-Shaped Macula on Optical Coherence Tomography
Yang, F.; Zhou, Y.; Zhang, B.; Yang, J.; Du, L.; Yu, C.; Chen, X.; Zhu, J.; Wang, Y.; He, X.
Show abstract
Purpose: To develop an interpretable automated pipeline for dome-shaped macula (DSM) detection and measurement from optical coherence tomography (OCT) B-scans. Methods: We analyzed one eye from each of 300 children aged 4-18 years in the Shanghai Child and Adolescent Large-scale Eye Study High Myopia (SCALE-HM) cohort (50 DSM-positive; 100 test eyes). A U-Net pretrained on OCTA-500 and fine-tuned on the development set segmented the retinal pigment epithelium (RPE) boundary. A geometric module located the apex, fitted a tangent-line baseline, and computed perpendicular height in physical coordinates. An eye was DSM-positive if any gradable B-scan had height >= 50 um. Two masked graders evaluated the test set; a third adjudicated disagreements. Results: The area under the receiver operating characteristic curve was 0.927 (95% confidence interval [CI], 0.850-0.986), sensitivity was 82.1% (95% CI, 64.4%-92.1%), and specificity was 100% (95% CI, 94.9%-100%) against the adjudicated reference. In concordant-positive eyes, automated height agreed with manual measurements (intraclass correlation coefficient, 0.949; mean absolute error, 6.9 um; bias, -5.7 um, versus Doctor A). Mean RPE-boundary error on pediatric test scans was 1.54 um. Conclusions: The pipeline may be considered a reliable and reproducible tool for automated DSM detection and height measurement on radial OCT, with each value traceable to landmarks on the source B-scan. External validation across populations, devices, and acquisition protocols is needed. Translational Relevance: The pipeline provides an objective and reproducible method to detect DSM and quantify dome height, width, and orientation across OCT meridians. Because each measurement can be verified on the source B-scan, it enables standardized DSM assessment.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Visible light optical coherence tomography of peripapillary retinal nerve fiber layer reflectivity in glaucoma 96%
- Two-Photon Microperimetry: A media opacity-independent retinal function assay 95%
- Relating Standardized Automated Perimetry Performed with Stimulus Sizes III and V in Eyes With Field Loss due to Glaucoma and NAION 95%
Similar papers in this journal
- Automated Expert-level Scleral Spur Detection and Quantitative Biometric Analysis on the ANTERION Anterior Segment OCT System 97%
- Macula structural and vascular differences in glaucoma eyes with and without high axial myopia 96%
- Optic nerve tortuosity and displacements during horizontal eye movements in healthy and highly myopic subjects 95%
Similar papers in this journal
- Development of the Advised Protocol for OCT Study Terminology and Elements Anterior Segment OCT extension reporting guidelines: APOSTEL-AS 96%
- Prediction of the ectasia screening index from raw Casia2 volume data for keratoconus identification by using convolutional neural networks 96%
- The evaluation of a web‐based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: a prospective open‐label method comparison study 95%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.