Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T
Alipour, A.; Chiu, M.; Alper, J.; Dyvorne, H.; Verma, G.; Rashid, S.; Teunissen, A. J. P.; Fayad, Z. A.; Balchandani, P.
Show abstract
Abstract: Purpose: Superparamagnetic iron oxide nanoparticles (SPION) are widely used as MRI contrast agents for cell tracking and molecular imaging. However, their detection using conventional T2/T2* weighted and susceptibility-weighted MRI relies on negative contrast (signal voids), which lacks specificity because similar hypointense signals can arise from other sources of magnetic susceptibility. This study introduces Frequency Shift Imaging (FSI), a positive-contrast technique based on an adiabatic Shinnar-Le Roux (SLR) self-refocused pulse that addresses the limited specificity of conventional SPION imaging. Methods: An adiabatic self-refocused RF pulse was designed using the SLR algorithm for frequency-selective positive-contrast imaging. The optimized pulse had a spectral bandwidth of 370 Hz, a peak RF amplitude of 14 T, and a duration of 15 ms. FSI data were acquired on a 7T MRI scanner. Phantom experiments used agarose-embedded 30 nm cell-labeled SPION at 0%, 25%, 75%, and 100% concentrations (pure). In vivo validation was performed following intramuscular SPION injection into the hind limb of a mouse. FSI images were compared with conventional acquisitions. Results: Quantitative phantom analysis showed normalized FSI signal intensities of 25.02% and 75.16% for samples containing 25% and 75% labeled cells, respectively, demonstrating an approximately proportional relationship between FSI signal and labeled-cell concentration. In vivo, FSI generated localized hyperintense positive contrast at the SPIO injection site, providing improved conspicuity and localization compared with the corresponding negative-contrast signal void. Discussion and Conclusion: FSI enables robust, B1-insensitive, positive-contrast SPION imaging at 7T with reduced echo time and SAR compared to paired adiabatic approaches, supporting its potential for quantitative cell tracking and molecular imaging applications.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T 96%
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 95%
- A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils 95%
Similar papers in this journal
Similar papers in this journal
- In-bore MRI-compatible Transrectal Ultrasound and Photoacoustic Imaging 92%
- Ultrasound-guided Photoacoustic image Annotation Toolkit in MATLAB (PHANTOM) for preclinical applications 91%
- In vivo co-registered hybrid-contrast imaging by successive photoacoustic tomography and magnetic resonance imaging 91%
Similar papers in this journal
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 94%
- Temporal signal-to-noise changes in combined multiband- and slice-accelerated echo-planar imaging with a 20- and 64-channel coil 94%
- The sensitivity of magnetic particle imaging and fluorine-19 magnetic resonance imaging for cell tracking 93%
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 94%
- Improved characterization of diffusion in normal and cancerous prostate tissue through optimization of the restriction spectrum imaging signal model 93%
- Magnetic Resonance Spectroscopy Spectral Registration Using Deep Learning 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.