Assessing respiratory rates and signs of air hunger using the PneumoRator sensor.
Hudson-Colby, J.; Baston, H.; Harding, M.; Brider, S.; Yates, F.; Shaban, M.; White, N. M.; Lewis, A.
Show abstract
Objectives: To investigate whether the PneumoRator wearable sensor could accurately assess Respiratory Rate (RR) and signs of air hunger (SAH) compared with clinician-observed assessment in adults with and without breathing pattern disorder (BrPD). Design: A pilot cross-sectional observational study. Setting: A research laboratory on a university campus. Participants: Healthy adults aged 18-40, who were not pregnant, no smokers or history of cardiovascular, respiratory or neurological illness. Thirty consented to the study, Twenty-nine had full data for analysis. Interventions: Participants wore the PneumoRator chest-worn sensor continuously for 10 minutes while seated at rest. Main outcome measures: Respiratory Rate was compared between PneumoRator-derived measurements and randomised 1-minute observer manual counts. Clinician-observed SAH and BrPD were assessed using the Breathing Pattern Assessment Tool (BPAT). Participants also completed the Nijmegen Questionnaire. PneumoRator signals were analysed to identify large-volume breaths as potential SAH events. Results: Thirty participants were recruited. Twelve participants met BPAT criteria for BrPD and four met Nijmegen Questionnaire criteria. There was no significant difference between manual and PneumoRator RR measurements (p=0.89). No significant difference was observed between methods for SAH detection (p=0.17). Participants with clinician-observed SAH demonstrated significantly higher PneumoRator signal amplitudes than those without SAH (p=0.035). Conclusion: The PneumoRator produced RR measurements comparable to clinician assessment and demonstrated potential for identifying signs of air hunger. Findings from this pilot study indicate that the PneumoRator device shows promise as a tool for continuous RR monitoring and as an adjunct to BrPD assessment. Larger clinical validation studies are now warranted.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- The physiological demands of Singing for Lung Health compared to treadmill walking 92%
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 91%
- Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients 91%
Similar papers in this journal
- Virtual reality exercise to help COVID patients with refractory breathlessness 92%
- COPD in the time of COVID-19: An analysis of acute exacerbations and reported behavioural changes in patients with COPD 91%
- Development and validation of a parent proxy bronchiectasis child quality of life instrument: The BC-QoL 91%
Similar papers in this journal
- Performance of EasyBreath ® Decathlon Snorkeling mask for Delivering Continuous Positive Airway Pressure 94%
- A Cross-sectional Feasibility Study to Evaluate the Usability and Efficacy of “Swaasa”: An AI-Platform for Rapid Respiratory Health Assessment 93%
- Kinematic signature of high-risk labored breathing revealed by novel signal analysis 93%
Similar papers in this journal
- Evaluating N95 Respirator Designs: A Mixed-Methods Pilot and Feasibility Study 93%
- Behaviour-based movement cut-off points in 3-year old children comparing wrist- with hip-worn actigraphs MW8 and GT3X 92%
- Effectiveness of a telenursing intervention program in reducing exacerbations in patients with chronic respiratory failure receiving noninvasive positive pressure ventilation: A randomized controlled trial 91%
Similar papers in this journal
- Brain activity measured by functional brain imaging predicts breathlessness improvement during pulmonary rehabilitation 91%
- Optimised oxygenation improves functional capacity during daily activities in patients with COPD on long-term oxygen therapy – a randomised crossover trial 91%
- Day-to-day Variability Indices improve utility of Oscillometry in Paediatric Asthma 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.