Speech Intelligibility Index (SII) as a Potential Referral Metric for Adult Cochlear Implant Candidacy Evaluation
Kong, J. A.; Tamati, T. N.; Moberly, A. C.; Neukam, J. D.
Show abstract
Objectives: The purpose of this pilot study was to investigate (1) if the Speech Intelligibility Index (SII) could be used to identify ears that meet cochlear implant (CI) candidacy beyond the "60/60" referral guidelines and (2) investigate the relationship between SII from patients' own hearing aids (HAs) and SII from optimally fit clinic-stock HAs such that a patient's own HAs can act as a proxy for an optimally fit HA and thus as a referral metric. Design: Prospective study of 23 participants ([≥] 18 years) with bilateral moderate to profound sensorineural hearing loss who were CI candidates in at least one ear. SII-Clinic (SII-C) values were recorded with probe-microphone measures using a Verifit II device (NAL-N2 targets) with speech stimuli presented at 60 dB A during patient CI evaluation in either their own HAs or clinic-stock HAs. SII values from participants' own HAs were recorded as part of a larger research protocol, thus SII-Personal (SII-P), with probe-microphone measures using a Verifit I device (NAL-RP targets) with pink noise stimuli presented at 65 dB A. Participants that did not wear HAs did not have SII-P calculated. Data was collapsed across ears. Correlation analysis between SII and best-aided consonant-nucleus-consonant (CNC) was conducted. Benchmark SII values were extrapolated using a best-fit line and CI candidacy rates reflecting various aided CNC scores that could be applied across CI centers. Nested logistic regression models were used to determine if the SII-C could improve model fit beyond the revised ear-specific 60/60 referral guideline. The relationship between SII-C and SII-P was assessed with Wilcoxon signed-rank test and Spearman correlation. Results: Correlation between SII-C and aided CNC score was r = 0.82 (p < 0.001), and the correlation between SII-P and aided CNC was r = 0.46 (p = 0.014). Extrapolated benchmarks of SII were calculated based on different CNC candidacy cutoffs, and benchmarks were able to capture at least 83% of the ears that met CNC candidacy cutoffs. SII was also found to improve model fit with word recognition score (WRS) and pure tone average (PTA) for 60% CNC candidacy cutoff ({chi}2 = 9.7; p = 0.002) and increased discrimination (AUC = 0.89 to AUC = 0.99). There was no significant difference between SII-C and SII-P using the Wilcoxon signed-rank test (p = 0.559). Conclusions: A larger study is needed that includes more ears that do not qualify for a CI; however, the results of this study demonstrate that (1) SII has the potential to be used in conjunction with the 60/60 referral guideline for CI candidacy evaluations and (2) SII can be used as a marker of audibility across different devices, including patients' own HAs, making SII an accessible metric during HA fittings and fine tunings.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Improved Sensitivity of Digits-in-Noise Test to High-Frequency Hearing Loss 96%
- Pinna-Imitating Microphone Directionality Improves Sound Localization and Discrimination in Bilateral Cochlear Implant Users 96%
- Longitudinal Electrocochleography as an Objective Measure of Serial Behavioral Audiometry in Electro-Acoustic Stimulation Patients 96%
Similar papers in this journal
- Speech in noise performance in adults with cochlear implants using a combined channel deactivation strategy with a variable number of dynamic focused channels 96%
- The Audible Contrast Threshold (ACT™) test: a clinical spectro-temporal modulation detection test 95%
- Brainstem Auditory Physiology in Children with Listening Difficulties 95%
Similar papers in this journal
- Validation of morphological ear classification devised by principal component analysis using three-dimensional images for human identification 92%
- Face Mask Fit Hacks: Improving the Fit of KN95 Masks and Surgical Masks with Fit Alteration Techniques 92%
- What do blind people "see" with retinal prostheses? Observations and qualitative reports of epiretinal implant users 91%
Similar papers in this journal
- Applicability of a short form of the Speech, Spatial und Qualities of Hearing Scale in 97 individuals with Meniere's disease in a multicentric registry 95%
- Neural adaptation at stimulus onset and speed of neural processing as critical contributors to speech comprehension independent of hearing threshold or age 94%
- Performance of ChatGPT in pediatric audiology as rated by students and experts 91%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.