A Comparative Analysis of Signal Quality and Morphological Fidelity in ECG Smartwatches
Muhammed, S. M.; Omran, N. A.; Sowelam, S.
Show abstract
This study provides a direct and objective comparison of ECG signal quality and morphological feature preservation across four leading commercial smartwatches: the Apple Watch Series 9, Samsung Galaxy Watch 6, Fitbit Sense 2, and Withings ScanWatch, using a controlled dataset. The Philips TC30 is used as the reference standard. ECG signal quality is assessed using Signal-to-Noise Ratio (SNR), Standard Deviation of Baseline Wander, and Power Spectral Density (PSD). Preservation of morphological features is assessed by comparing the performance of our automatic J-point and ST deviation detection algorithms when applied separately to recordings from each smartwatch. J-point detection is evaluated by comparing each device's performance against the reference device, while ST deviation is assessed using simulator-defined ground truth values. The Apple Watch and Withings ScanWatch achieved the best SNR, while the Samsung Galaxy Watch showed substantially lower values. The Withings ScanWatch demonstrated the most stable baseline, whereas the Fitbit Sense 2 showed the greatest baseline variability. All devices exhibited a consistent negative bias in J-point detection, suggesting that internal signal processing tends to smooth small changes in waveforms. For ST-segment classification, the Apple Watch achieved the most balanced performance in terms of sensitivity and specificity. These results provide researchers and clinicians with data-driven guidance for selecting the most appropriate device for their specific needs.
Matching journals
The top 9 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- An Open-Access Simultaneous Electrocardiogram and Phonocardiogram Database 95%
- Comparison of feature-based indices derived from photoplethysmogram recorded from different body locations during lower body negative pressure 95%
- Classification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020 95%
Similar papers in this journal
- Digitizing ECG image: new fully automated method and open-source software code 97%
- BRAVEHEART: Open-source software for automated electrocardiographic and vectorcardiographic analysis 96%
- An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method 94%
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.