Comparing advanced interference suppression algorithms for OPM-MEG
Pfeiffer, C.; Lundqvist, D.
Show abstract
On-scalp MEG using optically pumped magnetometers (OPMs) have become more widespread with the recent introduction of the first whole-head systems that offer comparable spatial sampling to conventional MEG systems. For these systems to become truly useful in neuroscience and clinically they need to be able to deal with the kind of interference seen in typical lab and hospital environments - both environmental and participant related (e.g., dental wires). Conventional MEG uses sophisticated interference suppression algorithms to deal with this, but these tend to become instable at lower sensor counts - which makes up the majority of OPM-MEG systems to date. Alternative methods for OPM-MEG are needed. Several alternative algorithms have been proposed but a clear comparison between them is lacking. Here, we test and compare 5 of the most promising candidates, namely homogenous field correction (HFC), adaptive multipole models (AMM), signal space projection (SSP), signal space separation (SSS) and its iterative implementation (SSSit) using simulations and data recorded with a whole-head system. Recorded data includes a participant with dental wire - an especially difficult to deal with source of interference. We find that all algorithms tested achieve good interference suppression with dual-axis data. With single-axis data, SSS exhibited stability problems and several algorithms showed large signal loss (up to ~25%). SSP, temporal SSS and temporal AMM were able to suppress the dental artifact. Finally, we provide recommendations for researchers to determine help decide how to deal with interference in their OPM-MEG studies.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG 96%
- Validating MEG source imaging of resting state oscillatory patterns with an intracranial EEG atlas 95%
- On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG 95%
Similar papers in this journal
- Optimizing magnetometers arrays and analysis pipelines for multivariate pattern analysis 97%
- Applying stochastic spike train theory for high-accuracy MEG/EEG 95%
- Time series analysis of trial-to-trial variability of MEG power spectrum during rest state, unattented listening and frequency-modulated tones classification 94%
Similar papers in this journal
- A comparison of automated and manual co-registration for magnetoencephalography 95%
- Comparing MEG and EEG measurement set-ups for a brain--computer interface based on selective auditory attention 94%
- How long is long? Word length effects in reading correspond to minimal graphemic units: An MEG study in Bangla 92%
Similar papers in this journal
- Potential of on-scalp MEG: Robust detection of human visual gamma-band responses 96%
- Data-driven beamforming techniques to attenuate ballistocardiogram (BCG) artefacts in EEG-fMRI without detecting cardiac pulses in electrocardiography (ECG) recordings 93%
- Methodology for tDCS integration with fMRI 93%
Similar papers in this journal
- Automated speech artefact removal from MEG data utilizing facial gestures and mutual information 95%
- Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG 95%
- EMG-projected MEG High-Resolution Source Imaging of Human Motor Execution: Brain-Muscle Coupling above Movement Frequencies 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.