In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model
Rybertt, M. V.; Liu, L. P.; Sahbaee, P.; McClung, G.; Mathew, M.; Noël, P. B.; Dhanaliwala, A. H.
Show abstract
Objectives: To evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging. Materials and Methods: A single healthy Yorkshire-Landrace pig was imaged on a clinical dual-source PCCT system (140 kVp; energy thresholds 20/55/72/90 keV; CTDIvol 12 mGy). Gadolinium K edge material-specific maps were generated with a calibration-based least-squares material decomposition. Three imaging protocols were evaluated for feasibility: (A) contrast dose testing for dynamic imaging with a hepatobiliary-clearing gadolinium contrast agent (0.2 and 0.8 mL/kg); (B) functional biliary imaging with dynamic and delayed acquisitions; and (C) dual-contrast imaging with simultaneous iodine and gadolinium decomposition. Attenuation (HU) and material concentrations (mg/mL) were measured from regions of interest. Results: Gadolinium was quantifiable in material-specific maps at a contrast dose of 0.8 mL/kg (arterial aortic signal, 114 {+/-} 4 HU and 1.4 {+/-} 0.3 mg/mL; delayed bile duct, 111 {+/-} 4 HU and 4.3 {+/-} 0.4 mg/mL). Hepatobiliary excretion was tracked over time, with bile duct gadolinium plateauing near 3.3 mg/mL approximately 15 minutes after injection. In the dual contrast acquisition, arterial gadolinium (2.5 {+/-} 0.7 mg/mL) and portal venous iodine (1.9 {+/-} 0.7 mg/mL) were separated within the liver, and both agents were separated within the ureters. Conclusions: In this proof of concept, gadolinium K-edge imaging was feasible on a clinical dual-source PCCT system for dynamic, functional biliary, and dual-contrast applications, supporting further development with improved material-decomposition sensitivity and confirmation in larger studies.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 94%
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 93%
- Contrast-enhanced photon-counting micro-CT of tumor xenograft models 92%
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 93%
- Developing a Fully Automated Imaging Biomarker for HCC Risk Assessment via MRI-Based Tumor Segmentation and EPM 92%
- An AI-based segmentation and analysis pipeline for high-field MR monitoring of cerebral organoids 90%
Similar papers in this journal
- First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging 95%
- Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks 91%
- Assessing GPT-4 Multimodal Performance in Radiological Image Analysis 90%
Similar papers in this journal
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 93%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 92%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.