Back

An interpretable, formally verified point-of-care ultrasound risk equation for difficult videolaryngoscopy: development and internal validation

Oyarzun-Silva, R. A.; Hernandez-Hernandez, P.; Fernandez-Vaquero, M. A.; De Luis-Cabezon, N.

2026-09-02 anesthesia
10.64898/2026.08.28.26361621 medRxiv
Show abstract

Background. Videolaryngoscopy still requires adjuncts or hyperangulated rescue in a clinically important minority, and bedside screening discriminates modestly. Point-of-care ultrasound (POCUS) of the anterior airway is a promising alternative, but existing prediction models are opaque or assume a pre-specified functional form. We developed and internally validated a parsimonious, fully disclosed POCUS risk equation whose form is recovered from data and whose structural properties are machine-checked by formal proof - to our knowledge the first formally verified clinical risk predictor - following TRIPOD+AI 2024. Methods. In a prospective single-centre, single-operator cohort of 259 adults undergoing elective videolaryngoscopy (no-Easy airway 68/259, 26.3%), Sequentially Thresholded Least Squares with bootstrap stability selection (B=300) screened a 71-term library of nine POCUS features and retained a seven-term logistic equation; a two-term bootstrap-stable model was pre-specified as robustness analysis. Internal validation used 5x10 repeated cross-validation plus temporal and device hold-outs, with pre-specified overfitting and optimism assessments. Five behavioural properties of the deployed equation were machine-checked in Lean 4. Results. Two interactions met the |c|/sigma_c>2 stability criterion: skin-to-epiglottis x skin-to-hyoid-bone distance and tongue volume x sagittal tongue area. The seven-term equation reached a 5x10 cross-validated C-statistic of 0.966 (optimism-corrected 0.968) and held across temporal and device hold-outs (0.94-0.97). Calibration-in-the-large matched prevalence, with cross-validated slope 0.90 attenuating to 0.625 out-of-time; standard recalibration restored 0.92 without loss of discrimination. The pre-specified two-term robustness model reproduced this performance (C-statistic 0.964-0.968; events-per-parameter 34; shrinkage 0.99), confirming the result is not an artefact of the screening stage. Net benefit over a clinical baseline was positive across 10-50% thresholds. All five Lean 4 theorems compiled without sorry. Conclusions. A sparse, formally verified POCUS equation predicts difficult videolaryngoscopy with high internally validated discrimination and quantified, modest overfitting. Because the equation was developed in a single-operator cohort and its inputs are operator-dependent, external validation requires prior harmonisation of the measurement protocol and operator credentialing.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.