The effectiveness of point of care high sensitivity troponin testing to improve Emergency Department flow: a multi-centre controlled interrupted time series

McHenry, R. D.; Saunders, A.; Ahmad, F.; Mackay, D.

2026-08-31 emergency medicine
10.64898/2026.08.27.26361548 medRxiv
Show abstract

Background Emergency Department (ED) crowding is an international crisis primarily driven by exit block. Point of care (POC) cardiac biomarker testing and reduced sampling intervals have been proposed to mitigate crowding by improving throughput, but whole-ED operational impacts remain poorly understood, and evaluations often rely on vulnerable observational designs. This study aimed to assess whether introducing POC high-sensitivity troponin testing and reduced sampling intervals changed whole-ED flow metrics, and to test the robustness of interrupted time series (ITS) methodology in this setting. Methods A multi-centre controlled interrupted time series (CITS) across two large urban intervention EDs and one untreated control ED in Glasgow, UK. The intervention combined whole-blood POC high-sensitivity troponin testing with a reduction in sampling intervals from 3 to 2 hours. Outcomes included daily ED admissions, mean occupancy, maximum occupancy, and mean length of stay. Analyses used a window of 120 days either side of each implementation date. Effects were evaluated using segmented ITS models, with and without controls, with permutation tests against 147 pre-intervention placebo dates. The minimum detectable effects of a similar study, applied to a national dataset, were simulated. Results Across 483,412 presentations to the intervention sites, the intervention produced no statistically significant change in any whole-ED flow metric against the untreated control at either site. Analysed alone, one intervention site appeared to show reductions in mean occupancy (-6.08, 95% CI -12.04 to -0.12) and maximum occupancy (-7.60, -14.47 to -0.73); the untreated control department produced reductions in the same direction at the same date, and both estimates attenuated to the null once the control was applied. Under a pre-specified 14-day transition specification the reductions in the untreated department reached statistical significance while those at the treated site did not. The study was limited by power due to the study window and limited control pool. Simulation demonstrated that a national dataset has the potential to provide operationally feasible and clinically important findings. Conclusion POC cardiac biomarker testing and reduced sampling intervals did not detectably improve whole-ED flow, though the design was underpowered. More importantly, uncontrolled ITS designs are highly vulnerable to confounding in complex healthcare systems; evaluations of operational interventions must utilise concurrent controls, and routinely report falsification tests.

Matching journals

The top 1 journal accounts for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.