Feasibility of a 2-Minute Multi-Echo UTE Acquisition for Simultaneous CT-Like Bone-Weighted Imaging and Quantitative T2* Mapping of Short-T2 Tissue
Do, H. P.; Bekku, M.; Berkeley, D.; Golden, M.; Kitane, S.; Uike, M.; Shinoda, K.; Takayanagi, R.; Takai, H.; Kawai, T.; Seballos, K.; Conley, R.; Sorfleet, K.; Devries, D.; Tymkiw, B.; AlGhuraibawi, W.; Caruthers, S. D.; Kadbi, M.; Provencher, M.; Tashman, S.; Ho, C. P.
Show abstract
Purpose: To determine the feasibility of a 2-minute multi-echo UTE (mecho-UTE) for CT-like bone-weighted contrast and T2* quantification of tissues with short T2/T2*. Methods: Mecho-UTE data acquired from four patients and five healthy subjects were used to assess image quality of the CT-like contrast. All data were reconstructed using conventional gridding (GRID+CONV) and compared with those reconstructed using conjugate gradient SENSE combined with deep learning-based denoising (CG+DLR). Image resolution and sharpness of the CT-like images were assessed using the full width at half maximum (FWHM) and relative edge sharpness (RESH), respectively. Calimetrix UTE-T2* phantom was used to assess the accuracy of T2* quantification of the mecho-UTE sequence. Results: Two-minute mecho-UTE with CG+DLR has similar accuracy (0.37 {+/-} 0.27 vs. 0.67 {+/-} 0.54 ms, p=0.20) and better precision (0.28 {+/-} 0.16 vs. 1.23 {+/-} 0.29 ms, p<0.001) compared to the 5-minute mecho-UTE with GRID+CONV. The 2-minute mecho-UTE with CG+DLR has higher resolution and sharpness compared to the 5-minute scan with GRID+CONV. Conclusion: It is feasible to achieve simultaneous CT-like contrast and T2* quantification of short-T2 tissues in two minutes. When appropriately used, it may simplify logistics, reduce costs, and eliminate radiation exposure risks.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Toward optimized intravoxel incoherent motion (IVIM) and compartmental T2 mapping in abdominal organs 94%
- Echo-planar imaging-based time-of-flight imaging using a modified interleaved flyback trajectory 94%
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T 94%
Similar papers in this journal
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 94%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 93%
- Contrast-enhanced photon-counting micro-CT of tumor xenograft models 93%
Similar papers in this journal
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 92%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 92%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 92%
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 93%
- MyoVision-US: an Artificial Intelligence-Powered Software for Automated Analysis of Skeletal Muscle Ultrasonography 92%
- Correcting B0 inhomogeneity-induced distortions in whole-body diffusion MRI of bone metastases 91%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.