Back

More Than Just Arm Movement: Finger-Worn Accelerometers Provide a Valid and Sensitive Alternative to Wrist-Worn Accelerometers for Measuring Real-World Upper-Limb Performance in Stroke Survivors

Dhamrongsirivadh, R.; Pugliese, B. L.; Civeriati, V.; Piela, K.; Fabara, E.; Vergara-Diaz, G.; Wang, Q. M.; Bonato, P.; Lee, S. I.

2026-08-17 rehabilitation medicine and physical therapy
10.64898/2026.08.13.26360286 medRxiv
Show abstract

Objective: To investigate the clinical validity of finger-worn accelerometers for providing a comprehensive assessment of upper-limb motor performance in stroke survivors in real-world environments, compared to wrist-worn accelerometers, and to examine how the clinimetric properties of wearable-based motor performance measures vary with the duration of patient data collection. Design: Cross-sectional observational design. Setting: Research laboratory and free-living environments. Participants: Twenty-seven stroke survivors aged 18-80 years with ischemic or hemorrhagic stroke at least six months prior to enrollment and mild-to-moderate upper-limb impairment without severe range-of-motion restrictions were enrolled. Three participants were ineligible and four withdrew, resulting in a final cohort of 20 participants (N = 20). Interventions: Not applicable. Main Outcome Measures: Wearable-based motor performance measures derived from fine-hand movements, gross-arm movements, and the combination of fine-hand and gross-arm movements captured by finger-worn and wrist-worn accelerometers in naturalistic settings for 6.4 {+/-} 1.8 days. Results: Wearable-based motor performance measures from fine-hand movements demonstrated the strongest convergent validity, known-group validity, and test-retest reliability, followed by those from combined and gross-arm movements. Convergent validity and test-retest reliability of wearable-based motor performance measures improved with longer monitoring durations, with four days being sufficient to obtain accurate and reliable upper-limb measures. Conclusions: Wearable-based motor performance measures from finger-worn accelerometers provide a more comprehensive assessment of upper-limb motor performance than those from wrist-worn accelerometers, supporting their use for real-world monitoring in stroke survivors. Furthermore, the improvements in clinimetric properties of wearable-based motor performance measures with longer monitoring durations highlight the importance of multi-day monitoring to mitigate day-to-day variability and ensure robust assessment.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.