LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes

De Lillo, F.; Smucler, J.

2026-08-07 bioengineering
10.64898/2026.08.06.743263 bioRxiv
Show abstract

Electrical stimulation (ES) and transepithelial/transendothelial electrical resistance (TEER) measurements are essential techniques in cell biology and tissue engineering, yet commercial devices for these applications cost between USD 2,500-9,000 and typically offer only one functionality. We present LATEER (Low-cost Arduino-based TEER and Electrical stimulation device), an open-source hardware platform that combines both ES and TEER measurement capabilities at a total cost below USD 100. The device features four independent channels, configurable pulsatile signals (amplitude up to 8.2 V, frequency 0.1-500 Hz, pulse width [&ge;]0.1 ms), and a resistance measurement range of 300 {Omega} to 1 M{Omega}, with <5% error for R {gtrsim} 4.7 k{Omega}. LATEER uses commercially available graphite pencil leads as electrodes ([~]USD 2 vs. USD 350 for commercial Ag/AgCl electrodes), which demonstrated excellent biocompatibility in cell culture. The system includes 3D-printed electrode holders compatible with standard 12-well and 24-well plates, allowing microscope visualization without electrode removal, and a Python-based graphical user interface for parameter configuration and real-time data acquisition. Because the electrodes remain fixed in the plate lid and only a single cable enters the incubator, both stimulation and resistance measurement can run continuously under standard culture conditions (37 {degrees}C, 5% CO2) without removing the plate or repositioning the electrodes, avoiding the temperature excursions and placement variability inherent to manual chopstick measurements. Validation with human pluripotent stem cell-derived cardiomyocytes demonstrated reliable frequency capture (electrical pacing) of the contracting monolayer, with a capture threshold between 250 and 400 mV/mm and controlled pacing across the 0.5-5 Hz range. TEER functionality was verified with mesenchymal stem cells, where the device resolved cell-density-dependent differences in electrical resistance in real time. All design files, firmware, and software are freely available under the CERN-OHL-S v2 license, enabling replication and customization by research laboratories worldwide. HighlightsO_LIAn open-source device combines electrical stimulation and TEER measurement under $100 C_LIO_LIGraphite electrodes offer biocompatibility at 0.6% cost of commercial alternatives C_LIO_LIFour independent channels with configurable parameters and real-time data logging. C_LIO_LIContinuous run setup in-incubator; no electrode repositioning needed C_LIO_LIValidated with stem cell-derived cardiomyocytes, achieving frequency capture (threshold 250-400 mV/mm) C_LIO_LI3D-printed holders enable microscope visualization without electrode removal C_LI Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=78 SRC="FIGDIR/small/743263v1_ufig1.gif" ALT="Figure 1"> View larger version (28K): org.highwire.dtl.DTLVardef@98f9deorg.highwire.dtl.DTLVardef@13c73aborg.highwire.dtl.DTLVardef@1cdf099org.highwire.dtl.DTLVardef@16ed0cf_HPS_FORMAT_FIGEXP M_FIG C_FIG Specifications Table O_TBL View this table: org.highwire.dtl.DTLVardef@4ef802org.highwire.dtl.DTLVardef@7c651borg.highwire.dtl.DTLVardef@d20013org.highwire.dtl.DTLVardef@102fc89org.highwire.dtl.DTLVardef@111b927_HPS_FORMAT_FIGEXP M_TBL C_TBL

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.