Analytical benchmarking of extraction-free lysis devices for molecular detection of tuberculosis
Jain, S.; Ball, A.; Anderson, C.; Cattamanchi, A.; Denkinger, C.; Steadman, A.; Yerlikaya, S.
Show abstract
Sample preparation remains a barrier for decentralized, swab-based molecular testing of tuberculosis (TB). Extraction-free workflows offer a simpler alternative, but systematic benchmarking against standard methods is lacking. We evaluated five novel lysis devices, BLINK Shaker Prototype, nPOC-BB, SPS-1, Truelyse, and Thermolyse, against a heat- and bead-beating reference method using contrived M. tuberculosis-spiked tongue and sputum swabs. The primary outcome was lysis efficiency, measured as the relative DNA recovery compared with the reference workflow. Secondary outcomes included nuclease inactivation, biosafety, and usability. In the reference buffer, lysis efficiencies ranged from 51-63% to 95-154% on tongue swabs and 12-54% to 280-644% on sputum swabs across the five devices. In proprietary buffers, performance varied more widely, with lysis efficiencies of 2-4% to 64-80% on tongue swabs and 1% to 94-398% on sputum swabs. Complete biosafety inactivation was achieved by three devices; two showed residual growth (<0.02%). Lysis efficiency of several devices met or exceeded the reference, supporting the feasibility of extraction-free workflows for TB diagnosis, with further optimization of buffer compatibility and biosafety profiles expected to enhance performance.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Performance characteristics of a high throughput automated transcription mediated amplification test for SARS-CoV-2 detection 94%
- Accuracy of tongue swab testing using Xpert MTB-RIF Ultra for tuberculosis diagnosis 94%
- A multicenter evaluation of a novel microfluidic rapid AST assay for Gram-negative bloodstream infections 94%
Similar papers in this journal
- Optimal processing of tongue swab samples for Mycobacterium tuberculosis detection by the Xpert MTB/RIF Ultra assay 96%
- Machine-learning based detection of adventitious microbes in T-cell therapy cultures using long read sequencing 95%
- Generation of false positive SARS-CoV-2 antigen results with testing conditions outside manufacturer recommendations: A scientific approach to pandemic misinformation 94%
Similar papers in this journal
- Lipobiotin-capture magnetic bead assay for isolation, enrichment and detection of Mycobacterium tuberculosis from saliva 95%
- Rapid SARS-CoV-2 testing in primary material based on a novel multiplex LAMP assay 95%
- ThermiQuantTM AquaStream: A Portable Instrument for Quantitative Colorimetric Isothermal Nucleic Acid Amplification Reactions in Paper and Tube Formats 94%
Similar papers in this journal
- Reducing the Cost of Rapid Antigen Tests through Swab Pooling and Extraction in a Device 95%
- SalivaSTAT: Direct-PCR and pooling of saliva samples collected in healthcare and community setting for SARS-CoV-2 mass surveillance 93%
- Evaluation and modelling of the performance of an automated SARS-CoV-2 antigen assay according to sample type, target population and epidemic trends 92%
Similar papers in this journal
- Validation of a Single-step, Single-tube Reverse Transcription-Loop-Mediated Isothermal Amplification Assay for Rapid Detection of SARS-CoV-2 RNA 93%
- Evaluation of sample collection and transport strategies to enhance yield, accessibility, and biosafety of COVID-19 RT-PCR testing 93%
- Acceptable Performance of the Abbott ID NOW Among Symptomatic Individuals with Confirmed COVID-19 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.