Back

Human decompression in real time: programmable ultrasound imaging during hyperbaric exposure

Currens, J.; Natoli, M. J.; Eltz, K.; Morales, G.; Bautista, K. J. B.; Dayton, P. A.; Lance, R.; Oralkan, O.; Yamaner, F. Y.; Moon, R. E.; Papadopoulou, V.

2026-07-27 physiology
10.64898/2026.07.22.737513 bioRxiv
Show abstract

The formation of inert gas bubbles during decompression can lead to decompression sickness (DCS), a major operational risk for divers, compressed-gas workers, astronauts, and high-altitude aviators. In diving, DCS risk is typically inferred from post-dive ultrasound detection of venous gas emboli (VGE), precluding modification of decompression schedules based on real-time physiological feedback. Two-dimensional ultrasound imaging could provide additional insight into decompression-related physiological changes; however, its use in hyperbaric environments has been largely precluded by fire risk associated with elevated oxygen partial pressures (ppO2) in enclosed spaces. Here, we developed a workflow for operating a programmable ultrasound system under hyperbaric conditions and acquiring ultrasound data from the subclavian vein and calf muscle during decompression. A total of 42 dives were conducted by 26 individuals using a previously characterized dive profile to 132 feet seawater (FSW) for 20 min with 9 min of decompression. Three exposure conditions were evaluated: non-exercising, exercising, and a brief pause at 20 FSW during compression. Twelve dives included programmable ultrasound imaging during decompression. Post-dive VGE responses were consistent with prior reports while demonstrating substantial inter-individual variability and sensitivity to modest profile modifications. VGE were detected in the subclavian vein during decompression in two participants and subsequently confirmed by post-dive echocardiography. Calf muscle ultrasound brightness typically increased from pre-dive to decompression measurements, before decreasing below baseline in the 120 min post dive measurement period. These findings demonstrate the feasibility of programmable ultrasound imaging during human decompression and establish a practical framework for ultrasound operation under hyperbaric conditions. This approach may support future physiological studies and development of automated decompression monitoring technologies. New and NoteworthyThis study demonstrates the first use of a programmable ultrasound system to acquire and quantitatively analyze ultrasound data during human decompression. The approach enabled direct visualization of venous gas emboli during decompression and revealed calf muscle ultrasound signal changes, providing a new tool for investigating physiological responses during decompression that are not accessible through conventional post-dive monitoring.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.