Back

Measurement of a panel of 21 steroids in a quantitative assay in human plasma, adipose tissue, and fecal samples using ultra-high-performance liquid chromatography-tandem mass spectrometry

Evstafev, I.; Krakstrom, M.; Saarinen-Aaltonen, N.; Hakkarainen, J.; Hakkinen, M. R.; Auriola, S.; Bostrom, P. J.; Poutanen, M.; Oresic, M.; Dickens, A. M.

2026-07-09 biochemistry
10.64898/2026.07.08.737297 bioRxiv
Show abstract

Comprehensive detection of steroids, beyond the limited panels typically analyzed in clinical chemistry laboratories, has become increasingly important given their pivotal roles in diverse biological processes. However, steroid quantification poses several analytical challenges, including differences in ionization efficiency and structural similarities across the entire steroid metabolic network. To address these challenges, we developed a targeted ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay to analyze 21 steroids using reverse-phase chromatography combined with rapid polarity switching. Mass spectrometry (MS) analysis was performed in scheduled multiple reaction monitoring (sMRM) mode. Depending on the steroid and matrix, the validated lower limits of quantitation (LLOQ) ranged from 12.0 pM to 1216 pM in plasma and 41.1 pM to 384 pM in fecal sample homogenates. In adipose tissue, it was from 0.01 pmol/g to 9 pmol/g. Measured steroid concentrations obtained from the commercial control samples (MassTrak Steroid Serum QC Set 1 and the MassCheck Steroid Panel 1 Serum Control) showed close agreement with the reference values. As a proof of concept, the method was successfully applied to 469 plasma samples in several projects, 15 adipose tissue samples, and 332 fecal samples, demonstrating its applicability to large-scale studies. In conclusion, the method enables sensitive, derivatization-free quantification of an expanded steroid panel in plasma and complex biological matrices, including adipose tissue and fecal samples, representing a significant advancement in comprehensive steroid profiling.

Matching journals

The top 9 journals account for 50% of the predicted probability mass.

1
Analytical Chemistry
218 papers in training set
Top 0.4%
11.0%
2
Scientific Reports
3612 papers in training set
Top 5%
9.6%
3
Metabolites
53 papers in training set
Top 0.1%
6.2%
4
Analytical and Bioanalytical Chemistry
18 papers in training set
Top 0.1%
4.8%
5
PLOS ONE
5266 papers in training set
Top 33%
4.3%
6
The Journal of Steroid Biochemistry and Molecular Biology
11 papers in training set
Top 0.1%
4.3%
7
Nature Communications
5641 papers in training set
Top 34%
3.5%
8
Communications Biology
993 papers in training set
Top 4%
3.5%
9
Talanta
14 papers in training set
Top 0.1%
3.2%
50% of probability mass above
10
Journal of Proteome Research
234 papers in training set
Top 0.8%
3.2%
11
The Analyst
16 papers in training set
Top 0.1%
3.2%
12
Analytical Biochemistry
26 papers in training set
Top 0.1%
3.1%
13
Journal of the Endocrine Society
15 papers in training set
Top 0.1%
2.4%
14
Metabolomics
14 papers in training set
Top 0.1%
2.4%
15
Communications Chemistry
48 papers in training set
Top 0.4%
2.1%
16
Journal of Biological Chemistry
690 papers in training set
Top 5%
1.9%
17
Analytica Chimica Acta
17 papers in training set
Top 0.2%
1.7%
18
npj Digital Medicine
118 papers in training set
Top 2%
1.7%
19
Biochemistry
148 papers in training set
Top 2%
1.3%
20
Biomolecules
100 papers in training set
Top 2%
1.1%
21
Molecular Omics
23 papers in training set
Top 0.3%
1.1%
22
Molecular & Cellular Proteomics
25 papers in training set
Top 0.3%
1.0%
23
ACS Omega
105 papers in training set
Top 4%
0.8%
24
Journal of Immunological Methods
24 papers in training set
Top 0.4%
0.8%
25
Chemical Research in Toxicology
10 papers in training set
Top 0.3%
0.8%
26
Cells
249 papers in training set
Top 7%
0.8%
27
Journal of Virological Methods
37 papers in training set
Top 0.6%
0.6%