Back

Multi-Site Reproducibility Study of 3D High-Content Analysis with Dual-View Oblique Plane Microscopy

Sparks, H.; Alexandrov, Y.; Arias-Garcia, M.; Bakal, C.; Batlle, E.; Bousgouni, V.; Carragher, N.; Colombelli, J.; Culley, J.; Curry, N.; Dent, L.; Dunsby, C.; Dvinskikh, L.; Garcia, E.; Giakoumakis, N. N.; Gustafsson, N.; Llanses, M.; Lee, M.; Mandke, K. N.; Marks, D.; McNeish, I.; Ratcliffe, C.; Sahai, E.; Suckert, T.

2026-07-03 bioengineering
10.64898/2026.06.29.735376 bioRxiv
Show abstract

High content imaging is being applied to achieve quantitative fluorescence readouts in increasingly complex 3-dimensional (3D) cell culture models such as spheroids and organoids. Compared to conventional 2D assays, 3D assays better represent biological heterogeneity but require more complex sample preparation, 3D imaging and 3D image analysis that can affect the accuracy and precision of such assays. We used spheroids formed from the NRAS-activated melanoma cell line 19161 modified to express an ERK kinase translocation reporter (KTR) as an exemplar 3D phenotypic assay carried out in 96-well plates. The spheroids were treated with the ERK activator TPA and a range of concentrations of the MEK inhibitor Binimetinib. 3D live-cell imaging with sub-cellular spatial resolution was performed using a dual-view oblique plane microscope (dOPM) - a form of single-objective light-sheet microscope - and the experiment was performed separately at 4 different institutes. The results were analysed using an identical 3D analysis pipeline and parameters. We assessed the variation in assay readout using a linear mixed effects model. Random variance at the well level was negligible (SD = 0.0048 relative to range of KTR biosensor readout at reference site of 0.17), indicating low technical noise. Treatment effects were dose-dependent and highly statistically significant compared to DMSO control across all sites (Dunnett-corrected p < 0.001). The range in KTR readout between the minimum (3.5 M Binimetinib) and maximum (100 nM TPA) treatments varied between 59 to 96% relative to the reference site. Measured bias in KTR readout between sites was between 6 and 12% of the range of the reference site. This study quantifies the reproducibility of a 3D live spheroid-based assay employing a fluorescence biosensor requiring readout out at the per-cell level using the dOPM platform and discusses areas where experimental protocol could be improved in the future to further improve reproducibility.

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

1
Biosensors and Bioelectronics
57 papers in training set
Top 0.1%
11.9%
2
Scientific Reports
3612 papers in training set
Top 3%
11.9%
3
Biomedical Optics Express
95 papers in training set
Top 0.2%
7.8%
4
ACS Sensors
49 papers in training set
Top 0.1%
6.7%
5
Lab on a Chip
96 papers in training set
Top 0.2%
6.7%
6
PLOS ONE
5266 papers in training set
Top 29%
5.5%
50% of probability mass above
7
The Analyst
16 papers in training set
Top 0.1%
5.5%
8
Journal of Biomedical Optics
28 papers in training set
Top 0.1%
3.2%
9
Journal of Biophotonics
16 papers in training set
Top 0.1%
2.4%
10
Nature Communications
5641 papers in training set
Top 40%
2.4%
11
Analytical Chemistry
218 papers in training set
Top 1%
2.4%
12
Methods
34 papers in training set
Top 0.2%
2.1%
13
BMC Methods
15 papers in training set
Top 0.1%
2.1%
14
Frontiers in Bioengineering and Biotechnology
98 papers in training set
Top 1%
1.7%
15
Communications Biology
993 papers in training set
Top 14%
1.7%
16
Advanced Biology
29 papers in training set
Top 0.3%
1.5%
17
Sensors
43 papers in training set
Top 0.8%
1.3%
18
Talanta
14 papers in training set
Top 0.2%
1.1%
19
SLAS Technology
14 papers in training set
Top 0.2%
1.1%
20
International Journal of Molecular Sciences
494 papers in training set
Top 12%
1.1%
21
Journal of Microscopy
20 papers in training set
Top 0.2%
1.0%
22
eneuro
439 papers in training set
Top 7%
0.9%
23
ACS Photonics
13 papers in training set
Top 0.2%
0.8%
24
Science Advances
1243 papers in training set
Top 30%
0.8%
25
Neurophotonics
42 papers in training set
Top 0.7%
0.6%
26
Journal of Cell Biology
392 papers in training set
Top 4%
0.6%