Back

Embedded transport accelerates interaction-limited biosensing

Dsouza, A.; Yang, Y.; Davies, T. S.; Brettschneider, J.; Haddleton, D. M.; Hand, R. A.; Ratnaraja, N.; Unnikrishnan, M.; Constantinidou, C.; Charmet, J.

2026-06-19 bioengineering
10.64898/2026.06.18.733113 bioRxiv
Show abstract

Phenotypic biosensors that measure bacterial viability and antimicrobial susceptibility are essential for rapid infectious disease diagnostics, yet their speed is fundamentally limited by the rate at which bacteria encounter reporter molecules, a transport bottleneck that has been typically addressed by complex microfluidic solutions. Here we show that this bottleneck can be overcome by engineering transport directly into the sensing material. A multifunctional ionic hydrogel matrix, co-encapsulating bacterial growth medium and the redox reporter resazurin, exploits swelling-driven convective transport to dramatically accelerate bacteria-reporter interactions without any change to assay chemistry. By systematically tailoring the hydrogel crosslinking density and optimizing the encapsulated nutrient-osmotic microenvironment, we maximize metabolic signal generation to achieve a 12-to-48-fold reduction in detection time relative to solution-phase and conventional hydrogel assays. Deployed in a standard 96-well format for urinary tract infection (UTI) diagnosis of 48 clinical samples, the platform rapidly detects infection in 15 minutes to 2 hours, achieving 95% sensitivity and 100% specificity for bacterial detection, and 100% sensitivity and 98% specificity for antimicrobial susceptibility profiling, compared to time-consuming gold-standard urine culture-based methods. Results are readable both quantitatively on a plate reader and visually as a colorimetric assay, enabling point-of-care deployment without additional instrumentation. Thus, embedding transport enhancement within the sensing matrix, represents a general and scalable design principle for accelerating interaction-limited biosensing, which has excellent scope for rapid diagnostic development.

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

1
Lab on a Chip
96 papers in training set
Top 0.1%
18.3%
2
Advanced Healthcare Materials
85 papers in training set
Top 0.2%
7.8%
3
Advanced Science
286 papers in training set
Top 0.8%
6.7%
4
ACS Nano
113 papers in training set
Top 0.3%
6.7%
5
Nature Communications
5641 papers in training set
Top 24%
6.7%
6
ACS Sensors
49 papers in training set
Top 0.1%
6.7%
50% of probability mass above
7
Advanced Functional Materials
46 papers in training set
Top 0.2%
5.5%
8
Advanced Materials
56 papers in training set
Top 0.2%
5.4%
9
Science Advances
1243 papers in training set
Top 6%
4.8%
10
Small
78 papers in training set
Top 0.5%
2.7%
11
Analytical Chemistry
218 papers in training set
Top 2%
1.7%
12
Advanced Materials Technologies
29 papers in training set
Top 0.3%
1.7%
13
Angewandte Chemie International Edition
93 papers in training set
Top 1%
1.5%
14
Biosensors and Bioelectronics
57 papers in training set
Top 0.5%
1.4%
15
ACS Central Science
71 papers in training set
Top 0.9%
1.3%
16
Nature Nanotechnology
32 papers in training set
Top 0.5%
1.1%
17
ACS Applied Materials & Interfaces
39 papers in training set
Top 0.7%
1.1%
18
Scientific Reports
3612 papers in training set
Top 66%
1.1%
19
Nature Chemical Biology
119 papers in training set
Top 2%
1.1%
20
Nature Chemistry
42 papers in training set
Top 0.8%
1.0%
21
Nano Letters
71 papers in training set
Top 1%
1.0%
22
ACS Applied Bio Materials
24 papers in training set
Top 0.8%
0.8%
23
Proceedings of the National Academy of Sciences
2444 papers in training set
Top 45%
0.6%
24
ACS Biomaterials Science & Engineering
37 papers in training set
Top 1%
0.6%