Back

Can Vision-Language Models See the Vital Signs? Benchmarking and Fine-Tuning for Intraoperative Monitor Reading

Gao, S.; Wang, P.; Zhao, X.; Yang, B.; Zhang, Z.; Feng, X.; He, Q.

2026-06-18 health informatics
10.64898/2026.06.10.26355351 medRxiv
Show abstract

Background Vital-sign deterioration is a leading contributor to preventable perioperative death, yet manual monitor reading is intermittent, error-prone, and subject to alarm fatigue. Automating this perceptual step could enable continuous surveillance, but existing solutions depend on device-specific hardware integration or cloud-hosted vision-language models (VLMs), which raise privacy, cost, and connectivity barriers in resource-limited healthcare facilities. Methods We constructed a benchmark of 200 in-the-wild intraoperative monitor photographs (spanning multiple vendors, angles, and illumination conditions) annotated for eight vital-sign parameters: heart rate, SpO2, ETCO2, respiratory rate, systolic/diastolic/mean blood pressure, and temperature. We evaluated an optical character recognition (OCR)-based pipeline, nine instruction-tuned VLMs (four commercial, five open-weight ranging from [≤]4B to 31B parameters) under two prompting regimes, and a compact open model (Qwen3.5-9B) adapted via low-rank fine-tuning (LoRA, 0.46% of parameters updated). Results Under a domain-aware prompt, frontier VLMs reached 0.98-0.997 exact-match accuracy zero-shot, whereas the OCR pipeline and [≤]4B model scored approximately 0.20 lower, defining a 9B-class usable floor. LoRA fine-tuning Qwen3.5-9B on 80-120 images raised accuracy from 0.953 to 0.994 (statistically indistinguishable from the best commercial model) and reduced the critical-error rate fivefold (0.0313 [->] 0.0063). Ablations showed that performance saturated at 80 training images and rank-8 adapters. Conclusion Monitor reading is a solved perception problem for VLMs above the 9B scale. A lightweight fine-tuned open model achieves frontier accuracy while running entirely on local hardware, preserving data privacy, offline capability, and near-zero marginal cost. Residual errors stem from blood-pressure source ambiguity and are addressable with explicit disambiguation logic.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.