Investigation of Intra-Fraction Stability and Inter-Fraction Reproducibility of Deep Inspiration Breath-Hold Across Two Hypofractionated Radiotherapy Regimens in the HYPORT Adjuvant Study.
MAHATA, A.; Roy, D.; Khatua, R.; Maity, S.; Barik, K.; Chakraborty, S.; Chatterjee, J.; Chatterjee, S.
Show abstract
Background: Deep Inspiration Breath Hold (DIBH) is a widely used respiratory motion management technique for minimizing cardiac dose in left-sided breast radiotherapy. In the Breast HYPORT Adjuvant study, DIBH was employed for cardiac sparing in patients without nodal irradiation using a standardized institutional protocol with the Varian Real-time Position Management (RPM) system. Both moderate-hypofractionation (control arm - 40Gy in 15 fractions) and one-week hypofractionation (experimental arm - 26 Gy in 5 fractions) regimens were delivered using this protocol. This study aimed to evaluate the robustness of DIBH by analyzing intra-fraction stability and inter-fraction reproducibility of breath-hold amplitude across the two treatment regimens. Methods: Respiratory waveforms acquired during each treatment session were analyzed to determine the median breath-hold amplitude and its standard deviation during beam delivery. Intra-fraction stability was assessed from vari- ations within individual treatment sessions, while inter-fraction reproducibility was evaluated relative to the simula- tion waveform amplitude across all treatment sessions. These parameters were compared between the two HYPORT regimens to examine breath-hold consistency during treatment delivery. Moreover, an additional comparison was made between the one-week hypofractionation regimen and the first five fractions of the moderate-hypofractionation regimen to evaluate the effect of treatment duration . Lung volumes from free-breathing and DIBH CT scans were analyzed to assess the effectiveness of patient breath-hold training. Results: Both arms demonstrated an average 1.7-fold increase of air volume in lung during the breath-hold position, confirming the effective implementation of DIBH during treatment planning and delivery. Structured training resulted in increased breath-hold amplitudes, with gains of 22.87% and 24.16% with respect to the first trial session in the experimental and control arms, respectively. Both regimens receive equivalent doses for approximately the same air volume in lung . Despite the different prescription doses in the two arms (26 Gy vs. 40 Gy), the experimental arm achieved an equivalent mean heart dose of 2.91% (75.6 cGy) compared with 2.95% (118.51 cGy) in the control arm, suggesting a similar cardiac preservation protocol adopted during treatment planning. Intra-fraction stability was similar between the control arm and the experimental arm, with median amplitude variations of 1.006 mm (95% CI: [0.998-1.015]) and 1.079 mm (95% CI: [1.067-1.097]), respectively. In contrast, inter-fraction reproducibility improved in the experimental arm, with lower deviation from simulation amplitude (0.44 {+/-} 0.24 mm vs. 0.66 {+/-} 0.25 mm) for the entire treatment schedule. The stability and reproducibility of experimental arm were further compared with the first five fractions of the control arm. The results were similar to those of the experimental arm. Conclusion: In this study, we compared two treatment regimens in terms of intra-fraction stability and inter-fraction reproducibility during DIBH radiotherapy. Both regimens demonstrated comparable intra-fraction stability, indicating effective motion management irrespective of treatment duration. However, the experimental arm showed better inter- fraction reproducibility, suggesting more consistent breath-hold performance throughout the treatment course. Based on stability and reproducibility, a reasonable narrowing of the DIBH gating window may be implemented with minor changes to the institutional protocol. The observed trend highlights the potential for improved consistency with the experimental approach and supports further investigation to better understand the underlying factors and strengthen these findings in future studies.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comprehensive Quantitative Evaluation of Inter-observer Delineation Performance of MR-guided Delineation of Oropharyngeal Gross Tumor Volumes and High-risk Clinical Target Therapy: An R-IDEAL Stage 0 Prospective Study 97%
- Initial Feasibility and Clinical Implementation of Daily MR-guided Adaptive Head and Neck Cancer Radiotherapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation 97%
- Cluster-Based Toxicity Estimation of Osteoradionecrosis via Unsupervised Machine Learning: Moving Beyond Single Dose-Parameter Normal Tissue Complication Probability by Using Whole Dose-Volume Histograms for Cohort Risk Stratification 97%
Similar papers in this journal
- Evaluation of indirect damage and damage saturation effects in dose-response curves of hypofractionated radiotherapy of early-stage NSCLC and brain metastases 97%
- First demonstration of the FLASH effect with ultrahigh dose-rate high-energy X-rays 96%
- Dosimetric and biologic intercomparison between electron and proton FLASH beams 96%
Similar papers in this journal
- Morphological changes after cranial fractionated photon radiotherapy: localized loss of white matter and grey matter volume with increasing dose 95%
- Detection of Alteration in Carotid Artery Volumetry Using Standard-of-care Computed Tomography Surveillance Scans Following Unilateral Radiation Therapy for Early-stage Tonsillar Squamous Cell Carcinoma Survivors: A Cross-Sectional Internally-Matched Carotid Isodose Analysis 94%
- Personalized volume-deescalated elective nodal irradiation in oropharyngeal squamous cell carcinoma (DeEscO): a study protocol 94%
Similar papers in this journal
- Cell lines of the same anatomic site and histologic type show large variability in intrinsic radiosensitivity and relative biological effectiveness to protons and carbon ions 96%
- Non-Invasive monitoring of normal tissue radiation damage using quantitative ultrasound spectroscopy 94%
- Evaluation of inverse treatment planning for Gamma Knife radiosurgery using fMRI brain activation maps as organs at risk 94%
Similar papers in this journal
- Standardising Breast Radiotherapy Structure Naming Conventions: A Machine Learning Approach 97%
- Effectiveness of FLASH vs conventional dose rate radiotherapy in a model of orthotopic, murine breast cancer 97%
- Quality of life and patient-reported outcomes following proton therapy for oropharyngeal carcinoma: a systematic review 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.