Singular Value Decomposition-Based Coil Combination Improves the Accuracy and Noise-Robustness of Quantitative Susceptibility Maps
Atkins, C.; Wu, T.; Bujak, B.; Inati, S.; Kellman, P.; Nair, G.
Show abstract
Most high-field MRI scanners conduct imaging using phased-array coils, in which the signals received by an array of coil elements are combined for downstream processing. Optimally combining these signals requires knowledge of each coil's spatial sensitivity profile, which can be acquired from a volume coil with homogeneous sensitivity across the field-of-view. However, this approach is not often used on high-field MRI scanners, especially on non-clinical systems; therefore, this work uses an algorithm based on the singular-value decomposition (SVD), called SVD-B1, to estimate coil sensitivities directly from the array data itself. Images produced by SVD-B1 are devoid of wormhole artifacts and open-ended fringe lines commonly seen in more conventional reconstructions. Quantitative Susceptibility Maps (QSMs) produced using the algorithm were compared to those produced using other combination algorithms across clinically relevant regions of in-vivo and postmortem human brains. As progressive levels of simulated noise were added to the data, SVD-B1's QSMs were up to 3% (in-vivo) and 13% (postmortem) more consistent (as measured by their Intraclass Correlation Coefficient) than those from other algorithms. Additionally, these QSMs were up to 8.5% (in-vivo) and 36% (postmortem) more accurate than other QSMs with respect to a "single-coil" reference. A parallel imaging extension of SVD-B1, called SVD-B1 GRAPPA, achieved similar results for QSMs generated from progressively more accelerated acquisition data. These results show that SVD-B1 can improve the sensitivity of high-resolution QSM to subtle changes in fine-grained tissue structures (e.g., in neurodegenerative disease) and help reduce scan times in clinical settings where shorter scans are imperative.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study 97%
- QSMxT: Robust Masking and Artefact Reduction for Quantitative Susceptibility Mapping 97%
- Combining Navigator and Optical Prospective Motion Correction for High-Quality 500 μm Resolution Quantitative Multi-Parameter Mapping at 7T 97%
Similar papers in this journal
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 96%
- Investigating the Effect of Flow Compensation and Quantitative Susceptibility Mapping Method on the Accuracy of Venous Susceptibility Measurement 96%
- MESMERISED: Super-accelerating T1 relaxometry and diffusion MRI with STEAM at 7 T for quantitative multi-contrast and diffusion imaging 96%
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 96%
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 95%
- Impact of acquisition and modeling parameters on test-retest reproducibility of edited GABA+ 94%
Similar papers in this journal
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 95%
- Improving spatial normalization of brain diffusion MRI to measure longitudinal changes of tissue microstructure in the cortex and white matter. 93%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.