Back

Overcoming oxygen impermeability in PDMS-free organ-on-a-chip microfluidics with nanoporous thermoplastic

Buck, F.; Bugter, J.; Kruckenbaum, G.; Staecker, I.; Harzi, M.; Lavrentieva, A.; Winkler, T. E.

2026-05-26 bioengineering
10.64898/2026.05.22.727128 bioRxiv
Show abstract

Oxygen availability is a critical yet all-too-often overlooked variable in organ-on-a-chip (OoC) systems. PDMS-based microfluidics remain the most common approach to facilitating oxygen equilibration with the incubator environment, but the materials tendency to ad- and absorb small hydrophobic molecules can pose significant concerns for pharmacological and toxicological studies. Yet there remains a lack of alternative gas-exchange materials feasible for OoC integration, even as the use of thermoplastic microfluidics in particular has otherwise proliferated. Here, we present commercially available track-etched nanoporous polycarbonate (50 nm pores, 1.18% porosity, [~]0.1 {euro}/cm2) as a practical alternative to polydimethylsiloxane (PDMS) for gas exchange in OoC. We show that nanoporous polycarbonate provides a thermoplastic material with an oxygen permeability of 3290 {+/-} 240 fs mol / kg, over an order of magnitude higher than PDMS. We demonstrate integration into existing lamination-based thermoplastic microfluidic fabrication workflows with sustained leak-free operation well above physiologically relevant pressures. We find that nanoporous polycarbonate does not compromise cell viability, but that high water vapor permeance necessitates a high-humidity environment around the device - though thickness-normalized water vapor permeability is notably similar to PDMS. We validate the OoC application with Caco-2 intestinal epithelial cells by monitoring oxygen levels during the critical cell attachment phase, with nanoporous polycarbonate allowing for maintenance of stable oxygen tension, in stark contrast to severe hypoxia in nonporous controls within 30 minutes. We further show that this uncontrolled hypoxia correlates with a time-delayed increase in cellular hypoxia inducible factor-1 reporter expression. Overall, our findings position nanoporous polycarbonate as a low-cost, mechanically robust, and fabrication-friendly alternative that can bring controlled oxygen availability to PDMS-free microfluidics and OoC.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
Lab on a Chip
96 papers in training set
Top 0.1%
27.0%
2
Advanced Materials Technologies
29 papers in training set
Top 0.1%
12.9%
3
Advanced Healthcare Materials
85 papers in training set
Top 0.2%
8.0%
4
Small
78 papers in training set
Top 0.1%
5.6%
50% of probability mass above
5
Biofabrication
36 papers in training set
Top 0.2%
4.1%
6
Advanced Functional Materials
46 papers in training set
Top 0.4%
3.6%
7
PLOS ONE
5266 papers in training set
Top 37%
3.3%
8
Scientific Reports
3612 papers in training set
Top 37%
2.8%
9
Advanced Science
286 papers in training set
Top 3%
2.5%
10
SLAS Technology
14 papers in training set
Top 0.1%
2.2%
11
Science Advances
1243 papers in training set
Top 19%
1.8%
12
Frontiers in Bioengineering and Biotechnology
98 papers in training set
Top 1%
1.8%
13
ACS Biomaterials Science & Engineering
37 papers in training set
Top 0.4%
1.8%
14
Langmuir
36 papers in training set
Top 0.3%
1.7%
15
Analytical Chemistry
218 papers in training set
Top 2%
1.5%
16
ACS Nano
113 papers in training set
Top 1%
1.5%
17
Annals of Biomedical Engineering
37 papers in training set
Top 0.8%
1.1%
18
Bioengineering & Translational Medicine
21 papers in training set
Top 0.5%
0.9%
19
ACS Omega
105 papers in training set
Top 4%
0.6%
20
Nature Communications
5641 papers in training set
Top 59%
0.6%
21
Materials Today Bio
20 papers in training set
Top 0.8%
0.6%
22
Small Methods
29 papers in training set
Top 0.9%
0.6%