Back

Combined Cartilage Thickness and Mechanical Property Mismatch Drives Local Strain Amplification at the Patellar Osteochondral Allograft Interface

Hernandez Lamberty, M. A.; Grant, J. A.; Arruda, E. M.; Coleman, R. M.

2026-05-17 bioengineering
10.64898/2026.05.13.724923 bioRxiv
Show abstract

Patellar osteochondral allograft (OCA) transplantation is widely used to treat large full-thickness cartilage defects, yet long-term failure and reoperation rates remain high. Although surface congruity and osseous integration are emphasized clinically, cartilage thickness and mechanical compatibility between donor and recipient are not considered. Our previous work suggests that cartilage thickness mismatch can amplify local deformation at the graft boundary, potentially compromising graft longevity. This study investigates how combined mismatches in cartilage thickness and mechanical properties influence the local strain environment at the patellar OCA interface. Simplified two-dimensional axisymmetric finite element models of patellar OCA repair were developed in ABAQUS. Donor-to-recipient cartilage thickness ratios ranging from 0.33 to 3.25 were evaluated together with donor-recipient Youngs modulus mismatches (2.5-7.0 MPa). Cartilage was modeled using homogeneous linear elastic and functionally graded material formulations to account for depth-dependent stiffness. A compressive pressure of 1.0 MPa was applied to represent patellofemoral joint loading, and peak compressive and shear strains were quantified at the graft boundary. Cartilage thickness mismatch produced localized high-strain regions (HSR) of compressive and shear strain at the donor-recipient interface that were absent in thickness-matched constructs. Strain amplification increased with both thickness and mechanical property mismatch. Compressive strain exhibited directional asymmetry, with donor-side-thicker configurations producing greater amplification than recipient-side-thicker configurations. Incorporating depth-dependent cartilage stiffness reduced peak strain magnitudes but did not eliminate mismatch-driven strain amplification. These findings demonstrate that cartilage thickness and mechanical disparity can create HSR at the patellar OCA graft boundary that may predispose grafts to impaired integration and long-term failure.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
Acta Biomaterialia
85 papers in training set
Top 0.1%
22.1%
2
Journal of Orthopaedic Research
19 papers in training set
Top 0.1%
12.1%
3
Journal of the Mechanical Behavior of Biomedical Materials
22 papers in training set
Top 0.1%
8.2%
4
Biomechanics and Modeling in Mechanobiology
25 papers in training set
Top 0.1%
7.0%
5
Annals of Biomedical Engineering
34 papers in training set
Top 0.2%
4.8%
50% of probability mass above
6
Cytotherapy
14 papers in training set
Top 0.1%
3.5%
7
Journal of Biomedical Materials Research Part A
18 papers in training set
Top 0.1%
3.5%
8
PLOS ONE
4510 papers in training set
Top 41%
3.2%
9
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 0.8%
2.7%
10
Tissue Engineering Part A
15 papers in training set
Top 0.1%
2.6%
11
Journal of Biomechanics
57 papers in training set
Top 0.3%
2.4%
12
Scientific Reports
3102 papers in training set
Top 51%
2.0%
13
Journal of Biomechanical Engineering
17 papers in training set
Top 0.1%
2.0%
14
Stem Cell Research & Therapy
30 papers in training set
Top 0.3%
1.9%
15
Biofabrication
32 papers in training set
Top 0.4%
1.9%
16
Advanced Healthcare Materials
71 papers in training set
Top 1%
1.7%
17
PLOS Computational Biology
1633 papers in training set
Top 17%
1.7%
18
Bioengineering
24 papers in training set
Top 0.5%
1.7%
19
Biomaterials Advances
20 papers in training set
Top 0.4%
1.5%
20
Osteoarthritis and Cartilage
30 papers in training set
Top 0.3%
1.2%
21
Biomaterials
78 papers in training set
Top 0.8%
1.1%
22
npj Regenerative Medicine
21 papers in training set
Top 0.3%
0.8%