Back

An 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization

Waks, M.; Bratch, A.; Mercer, T.; Lagore, R. L.; Moeller, S.; Thotland, J.; DelaBarre, L.; Auerbach, E.; Wu, X.; Vizioli, L.; Yacoub, E.; Ugurbil, K.; Adriany, G.; Sadeghi-Tarakameh, A.

2026-05-11 neuroscience
10.64898/2026.05.06.722982 bioRxiv
Show abstract

PurposeHigh-density RF receive arrays are required to realize the inherently available SNR and parallel imaging advantages at ultrahigh field strengths, which are essential for high-resolution functional and anatomical brain MRI. This study aims to systematically assess the impacts of often-overlooked parasitic losses associated with various RF coil components, as these losses can degrade the realized SNR and cause significant deviation from the ultimate intrinsic SNR (uiSNR; the theoretical upper bound of available SNR). In addition, we seek to detail engineering solutions to each of these loss mechanisms in pursuit of achieving a higher fraction of the uiSNR limit. MethodsA 16-channel loop-folded dipole transceiver array was developed for 10.5T human head applications and paired with a fully-updated 64-channel receive-only loop array. The optimization of the receive array considered several factors, including (but not limited to) coil dimensions to accommodate a larger population, the size and number of loops to enhance SNR and parallel imaging performance, and circuit design strategies to minimize parasitic losses. The SNR and parallel imaging performance of the receive array were quantitatively assessed by comparison with the uiSNR, as well as existing high-channel-count receive arrays at 7T and 10.5T. Finally, the complete 16-channel transmit, 80-channel receive coil array was safety validated for human use and employed for high-resolution functional and anatomical MRI at 10.5T. ResultsInitial results show that the 80-channel array, featuring larger loops in an overlapped layout with optimized circuitry, significantly improves the SNR and approaches the uiSNR limit in a large fraction of the head, while maintaining or enhancing the parallel imaging performance compared to previously used non-overlap layout. ConclusionThis study suggests that, although the traditionally used high-channel-count loop receive array technology can approach the uiSNR limit in the >10T regime, meticulous design optimization--including systematic assessment and minimization of parasitic losses--has become increasingly critical for achieving this goal in this new field-strength territory.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.