Noncoaxial Transcatheter Aortic Valve Deployment Creates Cusp-Specific Thrombogenic Microenvironments Through Altered Sinus Hemodynamics
Natarajan, T.; Kim, J. H.; Salgado, C. D.; Jha, A.; Baker, C.; Sellers, S. L.; Aslan, J. E.; Hinds, M. T.; Yoganathan, A. P.; Dasi, L. P.
Show abstract
BackgroundTranscatheter aortic valve replacement has transformed the management of aortic stenosis; however, adverse outcomes such as leaflet thrombosis and hypoattenuating leaflet thickening remain clinically significant concerns. Flow disturbances resulting from valve canting may alter local hemodynamics and promote thrombogenic conditions. We investigated how modest transcatheter heart valve canting alters cusp-specific sinus flow and washout and promotes localized thrombogenic microenvironments associated with leaflet surface thrombus formation using particle image velocimetry, a physiologic blood loop, and tissue analysis. MethodsA patient-derived aortic root model was used to evaluate the hemodynamic and thrombogenic effects of THV canting at -10{degrees} (anti-curvature), 0{degrees} (neutral), and +10{degrees} (along-curvature). High-resolution particle image velocimetry quantified sinus flow fields and washout characteristics, and complementary whole-blood loop experiments enabled histologic assessment of leaflet-associated thrombus formation. ResultsCanting redistributed systolic jet orientation and sinus recirculation in a direction-dependent manner while preserving global hemodynamic measurements. The most spatially constrained cusp showed the largest increase in stasis and the slowest washout. In the right coronary cusp, anti-curvature canting increased the fraction of sinus area with velocity magnitude <0.05 m/s to 92% versus 43% in neutral and 10% in along-curvature deployments, and prolonged neo-sinus (T90) washout to 4.7 cycles versus 2.9 and 1.8 cycles, respectively. Histology localized surface-adherent platelet/fibrin thrombus to these poorly washed regions, most prominently on the right coronary cusp leaflet in anti-curvature deployments. Left and noncoronary cusp responses shifted with tilt direction, indicating redistribution rather than uniform worsening of thrombogenic conditions. ConclusionsEven modest noncoaxial deployment is sufficient to create sinus-resolved throm-bogenic microenvironments that are not captured by global gradient or effective orifice area. Deployment configuration is therefore a modifiable determinant of post-TAVR leaflet throm-bosis risk and may contribute to HALT.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.