Back

Noncoaxial Transcatheter Aortic Valve Deployment Creates Cusp-Specific Thrombogenic Microenvironments Through Altered Sinus Hemodynamics

Natarajan, T.; Kim, J. H.; Salgado, C. D.; Jha, A.; Baker, C.; Sellers, S. L.; Aslan, J. E.; Hinds, M. T.; Yoganathan, A. P.; Dasi, L. P.

2026-04-21 bioengineering
10.64898/2026.04.17.719323 bioRxiv
Show abstract

BackgroundTranscatheter aortic valve replacement has transformed the management of aortic stenosis; however, adverse outcomes such as leaflet thrombosis and hypoattenuating leaflet thickening remain clinically significant concerns. Flow disturbances resulting from valve canting may alter local hemodynamics and promote thrombogenic conditions. We investigated how modest transcatheter heart valve canting alters cusp-specific sinus flow and washout and promotes localized thrombogenic microenvironments associated with leaflet surface thrombus formation using particle image velocimetry, a physiologic blood loop, and tissue analysis. MethodsA patient-derived aortic root model was used to evaluate the hemodynamic and thrombogenic effects of THV canting at -10{degrees} (anti-curvature), 0{degrees} (neutral), and +10{degrees} (along-curvature). High-resolution particle image velocimetry quantified sinus flow fields and washout characteristics, and complementary whole-blood loop experiments enabled histologic assessment of leaflet-associated thrombus formation. ResultsCanting redistributed systolic jet orientation and sinus recirculation in a direction-dependent manner while preserving global hemodynamic measurements. The most spatially constrained cusp showed the largest increase in stasis and the slowest washout. In the right coronary cusp, anti-curvature canting increased the fraction of sinus area with velocity magnitude <0.05 m/s to 92% versus 43% in neutral and 10% in along-curvature deployments, and prolonged neo-sinus (T90) washout to 4.7 cycles versus 2.9 and 1.8 cycles, respectively. Histology localized surface-adherent platelet/fibrin thrombus to these poorly washed regions, most prominently on the right coronary cusp leaflet in anti-curvature deployments. Left and noncoronary cusp responses shifted with tilt direction, indicating redistribution rather than uniform worsening of thrombogenic conditions. ConclusionsEven modest noncoaxial deployment is sufficient to create sinus-resolved throm-bogenic microenvironments that are not captured by global gradient or effective orifice area. Deployment configuration is therefore a modifiable determinant of post-TAVR leaflet throm-bosis risk and may contribute to HALT.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
Arteriosclerosis, Thrombosis, and Vascular Biology
65 papers in training set
Top 0.1%
18.8%
2
Circulation
66 papers in training set
Top 0.1%
18.8%
3
PLOS ONE
4510 papers in training set
Top 25%
6.9%
4
JACC: Basic to Translational Science
15 papers in training set
Top 0.1%
3.6%
5
Scientific Reports
3102 papers in training set
Top 35%
3.6%
50% of probability mass above
6
Nature Communications
4913 papers in training set
Top 42%
3.1%
7
JCI Insight
241 papers in training set
Top 2%
2.9%
8
PLOS Computational Biology
1633 papers in training set
Top 12%
2.6%
9
Biomechanics and Modeling in Mechanobiology
25 papers in training set
Top 0.3%
2.6%
10
BMC Cardiovascular Disorders
14 papers in training set
Top 0.8%
2.1%
11
Journal of the American Heart Association
119 papers in training set
Top 3%
1.9%
12
Annals of Biomedical Engineering
34 papers in training set
Top 0.6%
1.8%
13
Journal of Thrombosis and Haemostasis
28 papers in training set
Top 0.4%
1.7%
14
Journal of The Royal Society Interface
189 papers in training set
Top 3%
1.3%
15
International Journal for Numerical Methods in Biomedical Engineering
12 papers in training set
Top 0.2%
1.2%
16
Science Translational Medicine
111 papers in training set
Top 4%
1.2%
17
Nature Cardiovascular Research
28 papers in training set
Top 0.5%
0.9%
18
Journal of Biomechanics
57 papers in training set
Top 0.6%
0.9%
19
American Journal of Physiology-Heart and Circulatory Physiology
32 papers in training set
Top 1.0%
0.9%
20
Hypertension
32 papers in training set
Top 0.7%
0.8%
21
Journal of Applied Physiology
29 papers in training set
Top 0.5%
0.8%
22
Open Heart
19 papers in training set
Top 1%
0.8%
23
Science Advances
1098 papers in training set
Top 29%
0.8%
24
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.5%
0.8%
25
Acta Biomaterialia
85 papers in training set
Top 0.9%
0.8%
26
The American Journal of Cardiology
15 papers in training set
Top 1%
0.8%
27
American Journal of Respiratory and Critical Care Medicine
39 papers in training set
Top 0.9%
0.7%
28
npj Digital Medicine
97 papers in training set
Top 4%
0.7%
29
Journal of Neural Engineering
197 papers in training set
Top 2%
0.5%
30
Proceedings of the National Academy of Sciences
2130 papers in training set
Top 49%
0.5%